Bosch VMS Patch for BVMS-11.1.1.65: 383707, 390076 - Central Server service hangs after configuration activation
----------------------------------------------------------------------------------------------------------------

Patch ID: 383707, 390076
Patch Title: Central Server service hangs after configuration activation
Patch Target Version: BVMS-11.1.1.65


Patch Details:
----------------

This patch adresses issue 383707 and issue 390076 by improving the thread-synchronization in classes RcpClientProxy and SequencerMessageManager.
The patch produces in addition a finer-grained logging in those components of the BVMS Central Server where the processing of the activation of a new
configuration happens.


Problem Details:
----------------

Issue 383707 and issue 390076 can cause the problem that sometimes the Central Server service hangs after configuration activation.


Affected Bosch VMS Components / Machines:
-----------------------------------------

- Bosch VMS Management Server
- Bosch VMS Config Client


Uninstallation of the Patch:
----------------------------
Logon as a User with 'Administrator rights' or as the 'Administrator' itself
Open 'Control Panel'  'Programs'  'Programs and Features'  'View installed updates'
Select the Patch in the list and press 'Uninstall'

or

Start cmd.exe with 'RunAs Administrator'
Run the following command
msiexec.exe /I {ABE97F4F-8AC2-FADB-EE7C-2512330CA006} MSIPATCHREMOVE={253D26CB-3991-4769-970F-D826E6C5B962} /qb


List of Replaced Files:
-----------------------

- Bosch.Vms.Server.OnvifAdapter.dll [Version 11.1.1.76]
- Bosch.Vms.Service.Server.Modules.Vcs.VcsService.dll [Version 11.1.1.76]
- Bosch.Vms.Shared.Vcs.RcpCallSequencer.Impl.dll [Version 11.1.1.76]