Port
|
Displays the port number.
|
Level
|
Select Section or Path.
|
Received Trace Mode
|
Sets the trace expected string:
Off/None: Trace mode is disabled.
Auto: Uses the first string received from port at the other end as the baseline
string. An alarm is raised when a string that differs from the baseline is
received. For OC-N ports, Auto is recommended, since Manual mode requires
you to trace the circuit on the Edit Circuit window to determine whether the
port is the source or destination path.
Manual: Uses the Current Expected String field as the baseline string. An
alarm is raised when a string that differs from the Current Expected String is
received.
|
Disable FDI on TTIM?
|
If checked, disables the Forward Defect Indicator when a trail trace identifier mismatch is detected.
|
Transmit Area
|
Current Transmit String
|
Displays the current transmit string.
|
Transmit String Type
|
Sets the transmit string type to ASCII or Hex.
|
New Transmit String
|
Allows you to type a new transmit string.
|
Hex Mode
|
Displays the string in hexadecimal format.
|
Expected Area
|
Current Expected String
|
Displays the current expected string.
|
Expected String Type
|
Sets the expected string type to ASCII or Hex.
|
New Expected String
|
Allows you to type a new expected string.
|
Hex Mode
|
Displays the string in hexadecimal format.
|
Received Area
|
Current Received String
|
Displays the current received string.
|
Refresh
|
Refreshes the tab fields.
|
Auto-refresh
|
Allows you to select the auto-refresh rate for the PM values.
|
Hex Mode
|
Displays the string in hexadecimal format.
|
|
Apply
|
Applies changes made to all the fields in the tab.
|
Reset
|
Cancels any changes to the tab and returns the fields to their last-saved settings.
|
Help
|
Displays context-sensitive help.
|
Default
|
Restores the default values.
|