Opt Ampli Line > Parameters
The Opt Ampli Line > Parameters subtab allows you to view the OPT-BST, OPT-BST-L, OPT-PRE, and OPT-AMP-L optical amplifier line parameters.
Sets the port administration state. Choosing an administrative state from the drop-down list and clicking Apply changes the port's service state unless network conditions prevent the change. Admin states include:
IS-Puts the port in service. The port service state changes to IS-NR.
IS,AINS-Puts the port in automatic in-service. The port service state changes to OOS-AU,AINS.
OOS,DSBLD-Removes the port from service and disables it. The port service state changes to OOS-MA,DSBLD.
OOS,MT-Removes the port from service for maintenance. The port service state changes to OOS-MA,MT.
Shows an autonomously generated state that gives the overall condition of the port. Service states appear in the format: Primary State-Primary State Qualifier, Secondary State. For additional state information, see States.
Sets the direction of the ring that the port is on (east-to-west or west-to-east).
Displays the value of the optical power increase as a signal passes through the amplifier.
Displays the target gain value that needs to be maintained for the amplifier.
Displays the value of variation between signal peaks across the spectrum, calculated by CTC.
Sets the value of variation between signal peaks across the spectrum.
Sets the automatic in-service soak timer, which is the duration of time that must pass with an uninterrupted signal before the traffic/termination transitions to the IS-NR service state.
(Optical Preamplifier only) Displays the dispersion compensating unit insertion loss calculated by CTC.
Cancels any changes to the tab and returns the fields to their last-saved settings.