Provisionable Patchcords


Use the Provisionable Patchcord tab to provision a link that is advertised by OSPF throughout the network when a DCC or ITU-T G.709 GCC is not available. Provisionable patchcords, also called virtual links, are needed in the following situations:

Provisionable patchcords are required on both ends of a physical link. The provisioning at each end includes a local patchcord ID, slot/port information, remote IP address, and remote patchcord ID. Patchcords appear as dashed lines in CTC network view.

Note     To set up a provisionable patchcord between an optical port and a transponder/muxponder, an add/drop multiplexer, or multiplexer/demultiplexer port, the optical port must have SDCC/LDCC termination provisioned. If the port is the protection port in a 1+1 group, the working port must have SDCC/LDCC termination provisioned.

Item

Description

Origination ID

Displays the originating node patchcord ID (a value from 0 to 32767).

Origination Node

Displays the originating node ID.

Origination Shelf/Slot/Port

Displays the shelf, slot, and port information for the originating end of the patchcord.

Termination ID

Displays the terminating node patchcord ID (a value from 0 to 32767). The origination and termination IDs must be different if the patchcord is set up between two cards on the same node.

Termination Node

Displays the terminating node ID.

Termination Shelf/Slot/Port

Displays the shelf, slot, and port information for the terminating end of the patchcord. The origination port and the termination port must be different.

Create

Displays the Create a Provisionable Patchcord to create a new patchcord.

Delete

Deletes the highlighted patchcord.

Help

Displays context-sensitive help.