Enabling the Persistent FC ID Feature

If you connect to the switch from an AIX or HP-UX host, be sure to enable the persistent FC ID feature in the VSAN that connects these hosts.

A persistent FC ID assigned to an F port can be moved across interfaces and can continue to maintain the same persistent FC ID.

Restrictions

Detailed Steps

To enable the persistent FC ID feature, follow these steps:

  1. Expand Fabric > All VSANs and then select Domain Manager in the Logical Domains pane for the fabric and VSAN that you want to enable the Persistent FC ID feature for.
  2. You see the running configuration of the domain in the Information pane.

  3. Select the Persistent Setup tab and check the enable check box for each switch in the fabric that will have persistent FC ID enabled.
  4. Click the Apply Changes icon to save these changes.


Copyright 2010-2013, Cisco Systems, Inc. All rights reserved.