Error
|
Description
|
Workaround
|
|
fc1/1 : interface is not
down
|
FlexAttach configuration
fails because the
configuration is enabled
for an active interface with
the operation state as up.
|
To move the port to the shut state, enable the
FlexAttach configuration, and then move the port
to no shut state.
|
|
FlexAttach
configuration is not
distributed to the peers
|
The FlexAttach
configuration on one peer
NPV is not available to any
other peer NPV.
|
FlexAttach configuration will not be distributed
if cfs ipv4 distribute, or cfs ipv6 distribute is
disabled. Enable cfs ipv4 distribute, or cfs ipv6
distribute.
|
|
Even with CFS
distribution enabled
Inagua does not
become a peer with
other NPVs
|
CFS over IP is enabled,
and the Inagua in one
blade center is not the peer
NPV for other NPVs.
|
CFS over IP uses IP multicast to discover the
NPV peers in the network. IBM MM does not
support multicast and cannot act as a peer with
NPV. This prevents the FlexAttach configuration
from getting distributed to other peer NPVs in the
network.
|
|
NP port uses physical
pWWN instead of
virtual pWWN
configured through
FlexAttach
|
This occurs when NP port
uses physical pWWN
instead of virtual pWWN,
that is configured through
FlexAttach.
|
FlexAttach is supported on server interfaces such
as F ports, and not on external interfaces such as
NP ports.
|
|
real port WWN and
virtual WWN cannot
be same
|
This occurs when you try
to configure FlexAttach
with a similar value for
pWWN and virtual
pWWN.
|
Use different values for pWWN and virtual
pWWN, as similar values for pWWN and virtual
pWWn are not allowed.
|
|
Virtual port WWN
already exists
|
This occurs when you try
to configure an already
defined pWWN to a
different interface.
|
Use an undefined virtual pWWN for a new
interface.
|