Enabling 32-Bit and 64-Bit RMON Alarms for Physical Components
Detailed Steps
To configure an RMON alarm for a physical component for a 64-bit alarm, follow these steps:
- Choose Admin > Events > Threshold Manager and click the Physical tab.
You see the Threshold Manager dialog box with the Physical tab for the 64-bit alarm selected.
- Check the check box in the Select column for each variable to monitor.
- Enter the threshold value in the Value column.
- Enter the sampling period in seconds.
- Choose one of the following severity levels to assign to the alarm: Fatal(1), Warning(2), Critical(3), Error(4), Information(5).
- Click Create.
- Confirm the operation to define an alarm and a log event when the system prompts you to define a severity event.
If you do not confirm the operation, the system only defines a log event.
- Click More, and then click the 64-bit Alarms tab in the Threshold Manager dialog box to verify the alarm you created.
Note The MaxAlarm option is noneditable because of backend support. The max RMON alarms cannot be set using the CLI.
Copyright 2010-2013, Cisco Systems, Inc. All rights reserved.