4.21.7. PrmDebugLevelRVModule (Radvision Module)

Parameter Number: 0x1e2a

Description: The PrmDebugLevelRVModule parametertracks the Radvision Model. This is a bit-flag parameter, where the value is calculated according to the sum of the Radvision stack module values.

For example, to track the CM, CMAPI, and CMAPICB modules, add their values together (0x1 + 0x2 + 0x400 = 0x403) and enter this value for prmDebugLevelRVModule.

The following Radvision stack modules are the most used for debugging IPLink.

Table 60. Radvision Stack Modules - Common

Module Name

Description

Bit Number

Value

TPKTCHAN To view the content of the H.323 messages 7 0x80
UDPCHAN
8 0x100
CM Used for debugging purposes 0 0x1
CMAPI
1 0x2
CMAPICB
10 0x400

The following Radvision stack modules should not be used without first consulting technical support.

Table 61. Radvision Stack Modules - Technical

Module Name

Bit Number

Value

LI 2 0x4
LIINFO 3 0x8
SELI 4 0x10
PDLSRC 5 0x20
PDLCHAN 6 0x40
Q93 9 0x200
DEBUG 11 0x800
PI 12 0x1000
TIMER 13 0x2000
SOCKIO 14 0x4000
PDLAPI 15 0x8000
VT 16 0x10000
PDLMISC 17 0x20000
PDLLIST 18 0x40000
PDLCOMM 19 0x80000
PDLPRINT 20 0x100000
PDLFNERR 21 0x200000
PDLCONF 22 0x400000
PDLMTASK 23 0x800000
PDLTIMER 24 0100000
PDLSM 25 0x200000
PER 26 0x400000
CHANNELS 27 0x800000
NAMECHAN 28 0x1000000

Values: 0 to 0xffffff