4.13.1. Net_RingOn (Ring Cadence On-time)

Parameter Number: 0x9110

Description: The Net_RingOn parameter is one of two pulse signal used to define the ring cadence for HDSI and Dialogic Integrated Series boards. Net_RingOn defines the on-time signal and Net_RingOff defines the off-time signal. For detailed information about pulse signals and their associated values, see Pulse Signal and Pulse Example.

The value used for the MinTm, NomTm, and MaxTm (the same time must be used for all three values) is the total on-time duration of the pulse. If MinTm, NomTm, and MaxTm are set to 2000, then the total on-time duration of the pulse is 2000 milliseconds. The PostTm value is not included in the total on-time duration since this value defines part of the off-time duration.

Note: Only modifications to the MinTm, NomTm, and MaxTm values are supported. When modifying these values, the same time must be used for all three values.

Values: