PREV TOC HOME INDEX NEXT


3.1. Alarms

Alarms is used for sending and monitoring the alarm states on a T-1 or E-1 line. However, if you are already using LineAdmin to put lines into service, you may not need to use Alarms because LineAdmin displays much of the same information. Overall, LineAdmin is a more useful tool and should be used instead of Alarms in most cases. See Section 3.15, "LineAdmin".

Operating Systems: Windows, Linux

Command Line: alarms [parameter_list]

The Alarms utility uses the following command line parameters:

Parameter Description
-board <n> Board number (required). Use the Listboards utility to obtain the board number.
-line <n> Line number (required)

Example: This example monitors the alarm states on line 1 of board 0:

 alarms -board 0 -line 1

Display: Figure 1 shows the Alarms display.

Figure 1. Alarms Display

PREV TOC HOME INDEX NEXT

Click here to contact Dialogic Customer Engineering

Copyright 2001, Dialogic Corporation
All rights reserved