Previous PageTable Of ContentsHomeIndexNext Page


2.7. Call Analysis Errors

If ATDX_CPTERM( ) returns CR_ERROR, you can use ATDX_CPERROR( ) to determine the Call Analysis error that occurred.

#define

Error Description

CR_MEMERR

Out of memory trying to create temporary SIT tone templates (exceeds maximum number of templates).

CR_TMOUTON

Time-out waiting for an SIT tone.

CR_TMOUTOFF

SIT tone too long (exceeds a ca_mxtimefrq parameter).

CR_UNEXPTN

Unexpected SIT tone (the sequence of detected tones did not correspond to the SIT sequence).

CR_MXFRQERR

Invalid ca_mxtimefrq field in DX_CAP. If the ca_mxtimefrq parameter for each SIT tone is non-zero, it must have a value greater than or equal to the ca_timefrq parameter for the same SIT tone.

CR_UPFRQERR

Invalid upper frequency selection. This value must be non-zero for detection of any SIT tone.

CR_LGTUERR

Lower frequency greater than upper frequency.

CR_OVRLPERR

Overlap in selected SIT tones.


Previous PageTable Of ContentsTop Of PageIndexNext Page