6.3. IPSET_CALLINFO Parameter Set

Table 15 shows the parameter IDs in the IPSET_CALLINFO parameter set.

Table 15. IPSET_CALLINFO Parameter Set

Parameter ID

Type

Description

IPPARM_CALLID String, max. length = IP_CALLID_LENGTH (16 octets) The call ID. Note: In SIP, setting the call ID is not supported.
IPPARM_CALLDURATION unsigned long Duration of the call.
IPPARM_CONNECTIONMETHOD Enumeration, with one of the following values:
  • IPPARM_CONNECTION
    METHOD_FASTSTART
  • IPPARM_CONNECTION
    METHOD_SLOWSTART
The connection method: Fast Start or Slow Start. See Section 4.2, Using Fast Start and Slow Start Setup for more information.
IPPARM_DISPLAY String, max. length = MAX_DISPLAY_LENGTH (82), null-terminated. Display information. This information can be used by a peer as additional address information.
IPPARM_H245TUNNELING Enumeration, with one of the following values:
  • IP_H245TUNNELING_ON
  • IP_H245TUNNELING_OFF
Specify if tunneling is on or off. See Section 4.16, Enabling and Disabling Tunneling in H.323 for more information.
IPPARM_PHONELIST String, max. length = MAX_ADDRESS_LENGTH (128). Phone numbers that can be retrieved at the remote end point. Note: When issuing a gc_MakeCall( ), this information can also be sent through the numberstr parameter. See Section 3.4.11, gc_MakeCall( ) for more information.
IPPARM_USERUSER_INFO Uint8[ ], max size = MAX_USERUSER_INFO_LENGTH (131) User-to-user information.
Notes: For parameter IDs of type String, the length of the string when used in a GC_PARM_BLK is the length of the string plus 1. See Table 12, Summary of Parameter IDs and Set IDs for H.323 and SIP applicability.