4.14. GCIS_SET_TONE Parameter Set

Table 35 shows the parameter IDs for the GCIS_SET_TONE set ID.

Note: The GCIS_SET_TONE parameter set is not supported when using DM3 boards.

Table 35. GCIS_SET_TONE Parameter IDs 

Parameter ID

Type

Description

GCIS_PARM_TONE_AMP1 short Specifies the amplitude of the tone. The range is -40 to +3 dB.
GCIS_PARM_TONE_AMP2 short Specifies the amplitude of the tone. The range is -40 to +3 dB.
GCIS_PARM_TONE_DURATION unsigned short Specifies the duration of the tone in 10 ms units. The range is 1 to 65535. Set to -1 to play forever.
GCIS_PARM_TONE_FREQ1 unsigned short Specifies the frequency of the tone. The range is 200 to 3100 Hz.
GCIS_PARM_TONE_FREQ2 unsigned short Specifies the frequency of the tone. The range is 200 to 3100 Hz.
GCIS_PARM_TONE_OFF1 unsigned short Specifies the tone interval, in 10 ms units. The range is 0 to 65534 ms. Set to 0 to play a continuous tone.
GCIS_PARM_TONE_ON1 unsigned short Specifies the tone interval, in 10 ms units. The range is 1 to 65535 ms. Set to 1 or greater for continuous tone.
GCIS_PARM_TONE_TERMPARMLENGTH unsigned short Duration for which tone has to be played.