4.3. GCIS_SET_CALLPROGRESS Parameter Set

Table 23 shows the parameter IDs for the GCIS_SET_CALLPROGRESS set ID.

Note: The GCIS_SET_CALLPROGRESS parameter set is not supported when using DM3 boards.

Table 23. GCIS_SET_CALLPROGRESS Parameter IDs 

Parameter ID

Type

Description

GCIS_PARM_CALLPROGRESS_INDICATOR int Specifies the progress indicator. Valid values are:
  • CALL_NOT_END_TO_END_ISDN - In drop-and-insert configurations, the application has the option of providing this information to the network.
  • IN_BAND_INFO - In drop-and-insert configurations, the application has the option of notifying the network that in-band tones are available.
GCIS_PARM_CALLPROGRESS_TONETYPE unsigned char Indicates the type of call progress tone. Valid values are:
  • 0x01: Dialtone
  • 0x02: Busytone
  • 0x03: Reorder
  • 0x04: Ringback