3.3.1. TDM Bus Configuration of an Intel® NetStructure SS7 Board
For Intel® NetStructure SS7 board systems that use the CT Bus (to access voice circuits on a trunk connected to an Intel® NetStructure SS7 board, or for routing the SS7 signaling), the CT Bus clocking must be configured.
An Intel® NetStructure SS7 board can be configured to take its clock from the CT Bus, acting as an bus "slave", or to take it from one of its E-1 interfaces and act as a bus "master", providing the clock for all other boards on the CT bus.
For the Intel® NetStructure SS7 ISA (PCCS6) board, the
PCCS6_BOARDcommand in the config.txt file should have its flags argument set as indicated in Table 4.
SCbus Slave 0x00C2 SCbus Master - clock from LIU1 0x0043 SCbus Master - clock from LIU2 0x0047 SCbus Master - Intel® NetStructure SS7 board internal clock 0x0042 For Intel® NetStructure SS7 CompactPCI and PCI boards, the
SEPTELCP_BOARDandSEPTELPCI_BOARDcommands respectively in the config.txt file should have the flags argument set to one of the values indicated in Table 5.
CT Bus Slave 0x00C2 CT Bus Master - clock from one of the line interfaces 0x0043 CT Bus Master - Intel® NetStructure SS7 board internal clock 0x0042
Click here to contact Telecom Support Resources