3.6. Importing Pre-Defined Configuration Profiles (PRF Files)

Figure 54. Configurator Window


  1. Click the Import Predefined Config... button from the Dialogic GDK Configurator Main tab. The Open Profile window displays.

Figure 55. Open Profile Window


Figure

  1. Select the appropriate profile (.prf) files from the c:\fax (%GFAX%) directory.
NOTES:
1. Importing pre-defined PRF Network Profiles results in assigning recommended parameters that may be displayed through the following tabs of the Dialogic GDK Configuration Utility (GammaLink, ISDN In, ISDN Out, Error Mapping, Debug).
2. It is recommended NOT to modify these pre-defined parameters.
3. Parameters accessible via the Dialogic GDK Configuration Utility are not used by all configurations. Refer to Appendix D for a list of parameters used for each configuration.

The possible .prf files are dependent on the protocol used. Select the appropriate .prf file from the following tables.


Table 9. ISDN T1 Protocol Profiles

PROTOCOL

PRF FILE

4ESS

gdk_isdn_4ess_CPi2400CTT1.prf

5ESS

gdk_isdn_5ess_CPi2400CTT1.prf

DMS

gdk_isdn_dms_CPi2400CTT1.prf

NTT

gdk_isdn_ntt_CPi2400CTT1.prf


Table 10. ISDN E1 Protocol Profiles

EURO ISDN

gdk_isdn_net5_CPi3000CTE1.prf


Table 11. T1 CAS Setup (Robbed Bit Signaling) Protocol Profiles

PROTOCOL

PRF FILE

CAS T1 E&M

gdk_cas_em_CPi2400CTT1.prf

CAS T1 Loop Start

gdk_cas_ls_CPi2400CTT1.prf

CAS T1 Ground Start

gdk_cas_gs_CPi2400CTT1.prf

When you import one of these .prf files, you will be prompted to enter the number of trunks installed in the chassis.


Figure 56. How Many Trunks Dialog Box


Figure

Select the number of trunks installed in the chassis. Proposed choices are from 1 to 4 in T1 mode, and 1 to 3 in E1 mode.

The possible .prf files are dependent on the protocol used. Select the appropriate .prf file from the following table.


Table 12. ISDN E1 Protocol Profiles

PROTOCOL

PRF FILE

DASS2

gdk_isdn_dass2_DTI300_CPi3000CT.prf

When you import one of these .prf files, you will be prompted to enter the number of trunks installed in the chassis.


Figure 57. How Many Trunks Dialog Box


Figure

Select the number of trunks installed in the chassis. Proposed choices are from 1 to 4 in T1 mode, and 1 to 3 in E1 mode.

The possible .prf files are dependent on the protocol used. Select the appropriate .prf file from the following tables.


Table 13. ISDN T1 Protocol Profiles

PROTOCOL

PRF FILE

4ESS

gdk_isdn_4ess_DTI240_CPsc.prf


Table 14. ISDN E1 Protocol Profiles

DASS2

gdk_isdn_dass2_DTI300_CPsc.prf

EURO ISDN

gdk_isdn_net5_DTI300_CPsc.prf

When you import one of these .prf files, you will be prompted to enter the number of trunks installed in the chassis.


Figure 58. How Many Trunks Dialog Box


Figure

Select the number of trunks installed in the chassis. Proposed choices are from 1 to 4 in T1 mode, and 1 to 3 in E1 mode.

The possible .prf files are dependent on the hardware used. Select the appropriate .prf file from the following table.


Table 15. DM3 SCbus Profiles

CPi/2400CT

gdk_SCBus_CPi2400CT.prf

CPi/3000CT

gdk_SCBus_CPi3000CT.prf

The possible .prf files are dependent on the hardware and protocol used. Select the appropriate .prf file from the following table.


Table 16. BRI/2VFD Profile

BRI/2VFD in EURO ISDN Mode

gdk_bri_euro_bri2vfd.prf

These configurations include:

No .prf file is needed to support these configurations.

NOTE:
If a .prf file is accidentally imported, click the Restore Default Configuration button from the Dialogic GDK Configurator Main tab to restore the default settings.