DPNSS Message Types for cc_SndMsg( )

The following tables describe the ISDN message types that support the DPNSS protocol.

Field

Description

Field Selection

Definition

1. Length

Total bytes of the following data field

4 + length of Diverted Number

Required value

2. Data

Diversion IE ID

DIVERSION_IE

Identifies the Diversion IE

3. Data

Diversion IE Length

2 + length of Diverted Number

Number of data bytes for this IE

4. Data

Diversion Type

DIVERT_IMMEDIATE

Diverted immediately

   

DIVERT_ON_BUSY

Diverted when called party was busy

   

DIVERT_NO_REPLY

Diverted when called party did not answer

5. Data

Diversion Location

DIVERT_LOCAL

DIVERT_REMOTE

Local diversion

Remote diversion

6. Data

Diversion Number

ASCII string

Diverted number

Field

Description

Field Selection

Definition

1. Length

Total number of bytes of the following data field

3

Required value

2. Data

Intrude IE ID

INTRUDE_IE

Identifies the Intrude IE

3. Data

Intrude IE Length

1

Number of data bytes for this IE

4. Data

Intrude Type

INTRUDE

INTRUDE_WITHDRAW

Intrude

Withdraw intrusion

Field

Description

Field Selection

Definition

1. Length

Total bytes of the following data field

4 + length of NSI String

Required value

2. Data

NSI IE ID

NSI_IE

Identifies the NSI IE

3. Data

NSI IE Length

2 + length of Network Specific Indications (NSI) string

Number of data bytes for this IE

4. Data

NSI Message Type

NSI_EEM

NSI_LLM

End-to-end message

Link-to-link message

5. Data

NSI String Length

Length of Network Specific Indications (NSI) string

Length of next NSI string

6. Data

NSI String

ASCII string

Network Specific Indications string

NOTE:
NSI IE fields 5 and 6 can be repeated multiple times as needed.

Field

Description

Field Selection

Definition

1. Length

Total bytes of the following data field

3

Required value

2. Data

Transfer IE ID

TRANSFER_IE

Identifies the Transfer IE

3. Data

Transfer IE Length

1

Number of data bytes for this IE

4. Data

Transfer Direction

TRANSFER_ORIG

TRANSFER_TERM

Originating end

Terminating end

1. Length

Total bytes of the following data field

2 + Length of Transit Data

Required value

2. Data

Transit IE ID

TRANSIT_IE

Identifies the Transit IE

3. Data

Transit IE Length

Length of Transit Data

Number of data bytes for this information element

4. Data

Transit Data

data

Transit data received from a CCEV_TRANSIT event


Previous PageTable Of ContentsTop Of PageIndexNext Page