Appendix C - DTMF and MF Tone Specifications


Table 23. DTMF Tone Specifications

Code

Tone Pair Frequencies (Hz)

Default Length (ms)

1

697, 1209

100

2

697, 1336

100

3

697, 1477

100

4

770, 1209

100

5

770, 1336

100

6

770, 1477

100

7

852, 1209

100

8

852, 1336

100

9

852, 1477

100

0

941, 1336

100

*

941, 1209

100

#

941, 1477

100

a

697, 1633

100

b

770, 1633

100

c

852, 1633

100

d

941, 1633

100


Table 24. MF Tone Specifications (CCITT R1 Tone Plan)

Code

Tone Pair Frequencies (Hz)

Default Length (ms)

Name

1

700, 900

60

1

2

700, 1100

60

2

3

900, 1100

60

3

4

700, 1300

60

4

5

900, 1300

60

5

6

1100, 1300

60

6

7

700, 1500

60

7

8

900, 1500

60

8

9

1100, 1500

60

9

0

1300, 1500

60

0

*

1100, 1700

100

KP

#

1500, 1700

60

ST

a

900, 1700

60

ST1

b

1300, 1700

60

ST2

c

700, 1700

60

ST3

    • The standard length of a KP tone is 100 ms.