The voice board parameter defines have a "DXBD_" prefix.
The board parameter defines, default settings, read/write privileges, and descriptions follow.
Table 4. Voice Board Parameters
|
|
Read/ |
|
|
DXBD_CHNUM |
1 |
R |
- |
Channel Number - number of channels on the board |
DXBD_FLASHCHR |
1 |
R/W |
& |
Flash character - character that causes a hook flash when detected. |
DXBD_FLASHTM |
2 |
R/W |
50 |
Flash Time - length of time onhook during flash |
DXBD_HWTYPE |
1 |
R |
- |
Hardware Type - value can be: TYP_D40: D/40 board TYP_D41: D/21, D/41, |
DXBD_MAXPDOFF |
2 |
R/W |
50 |
Maximum Pulse Digit Off - max. time loop current may be off before the existing loop pulse digit is considered invalid and reception is reinitialized |
DXBD_MAXSLOFF |
2 |
R/W |
25 |
Maximum Silence Off - maximum time for silence being off, during audio pulse detection |
DXBD_MFDELAY |
2 |
R/W |
6 |
MF Interdigit Delay - The length of the silence period between tones during MF dialing. This parameter affects all the channels on the board. (10 ms units) |
DXBD_MFLKPTONE |
2 |
R/W |
10 |
MF Length of LKP Tone - The length of the LKP tone during MF dialing. This parameter affects all the channels on the specified board. Maximum value: 15 (10 ms units) |
DXBD_MFMINON |
2 |
R/W |
0 |
Minimum MF On - The duration to be added to the standard MF tone duration before the tone is detected. The minimum detection duration is 65 ms for KP tones and 40 ms for all other tones. This parameter affects all the channels on the board. (10 ms units) |
DXBD_MFTONE |
2 |
R/W |
6 |
MF Minimum Tone Duration - The duration of a dialed MF tone. This parameter affects all the channels on the board. Maximum value: 10 (10 ms units) |
DXBD_MINIPD |
2 |
R/W |
25 |
Minimum Loop Interpulse Detection - minimum time between loop pulse digits during loop pulse detection |
DXBD_MINISL |
2 |
R/W |
25 |
Minimum Interdigit Silence - minimum time for silence on between pulse digits for audio pulse detection |
DXBD_MINLCOFF |
2 |
R/W |
0 |
Minimum Loop Current Off - minimum time before loop current drop message is sent |
DXBD_MINOFFHKTM |
2 |
R/W |
250 |
Minimum offhook time (10 ms) |
DXBD_MINPDOFF |
1 |
R/W |
2 |
Minimum Pulse Detection Off - minimum break interval for valid loop pulse detection |
DXBD_MINPDON |
1 |
R/W |
2 |
Minimum Pulse Detection On - minimum make interval for valid loop pulse detection |
DXBD_MINSLOFF |
1 |
R/W |
2 |
Minimum Silence Off - min. time for silence to be off for valid audio pulse detection |
DXBD_MINSLON |
1 |
R/W |
1 |
Minimum Silence On - min. time for silence to be on for valid audio pulse detection |
DXBD_MINTIOFF |
1 |
R/W |
5 |
Minimum DTI Off - minimum time required between rings-received events |
DXBD_MINTION |
1 |
R/W |
5 |
Minimum DTI On - minimum time required for rings received event |
DXBD_OFFHDLY |
2 |
R/W |
50 |
Offhook Delay - period after offhook, during which no events are generated e.g., no DTMF digits will be detected during this period. |
DXBD_P_BK |
2 |
R/W |
6 |
Pulse Dial Break - duration of pulse dial off-hook interval |
DXBD_P_IDD |
2 |
R/W |
100 |
Pulse Interdigit Delay - time between digits in pulse dialing |
DXBD_P_MK |
2 |
R/W |
4 |
Pulse Dial Make - duration of pulse dial offhook interval |
DXBD_PAUSETM |
2 |
R/W |
200 |
Pause Time - delay caused by a comma in the dialing string |
DXBD_R_EDGE |
1 |
R/W |
ET_ROFF |
Ring Edge - detection of ring edge, values can be: ET_RON: beginning of ring ET_ROFF: end of ring |
DXBD_R_IRD |
2 |
R/W |
80 |
Inter-ring Delay - maximum time to wait for the next ring (100 ms units). Used to distinguish between calls. Set to 1 for T-1 applications. |
DXBD_R_OFF |
2 |
R/W |
5 |
Ring-off Interval - minimum time for ring not to be present before qualifying as "not ringing" (100 ms units) |
DXBD_R_ON |
2 |
R/W |
3 |
Ring-on Interval - minimum time ring must be present to qualify as a ring (100 ms units) |
DXBD_S_BNC |
2 |
R/W |
4 |
Silence and Non-silence Debounce - length of a changed state before Call Status Transition message is generated |
DXBD_SYSCFG |
1 |
R |
- |
System Configuration - JP8 status for D/4x boards: 0 = loop start interface (JP8 in).; 1 = DTI/xxx interface (JP8 out): |
DXBD_T_IDD |
2 |
R/W |
5 |
DTMF Interdigit delay (time between digits in DTMF dialing) |
DXBD_TTDATA |
1 |
R/W |
10 |
DTMF length (duration) for dialing. |
Click here to contact Dialogic Customer Engineering
Copyright 2002, Dialogic Corporation