Previous PageTable Of Contents../index.htmlIndexNext Page


5. SCbus Digital Service Inbound/Outbound Call Routing Example


Top Of PageSCbus Call Routing Example Overview

In this example, an incoming call on a T-1 time slot received by the T-1 device on the first D/240SC-T1 board is passed to the T-1 device on the second D/240SC-T1 board, see Figure 4 and Figure 5. To make this connection, full duplex communications must be established between digital channel 12 on the first D/240SC-T1 board and digital channel 23 on the second D/240SC-T1 board. Figure 4 shows the SCbus time slot connections established at system initialization to the digital transmit channels used in this example.


Previous PageTable Of ContentsTop Of PageIndexNext Page

Click here to contact Dialogic Customer Engineering