Previous Page Table Of Contents../index.html IndexNext Page


2.1.  SCX160 SCxbus Adapter Features

The SCX160 SCxbus Adapter converts internal SCbus TTL signals into external SCxbus RS485 type signals, and vice-versa, for communications between SCSA devices installed in up to 16 PC hosts. Each SCX160 SCxbus Adapter is assigned a unique node identification number.

The SCX160 SCxbus Adapter platform incorporates the following:

The SCX160 SCxbus Adapter supports the following:

At Dialogic Service startup the SCX160 SCxbus Adapter runs a start-up test program that verifies on-board functionality. The start-up test program executes the following tests:

In addition to these diagnostics, the SCX160 SCxbus Adapter continuously monitors operations and reports alarms when they are software enabled and when user-defined thresholds are exceeded. Alarms are transmitted to the application to be handled by the application or the system administrator. Alarms report the following kinds of problems:

The following table provides the technical specifications for the SCX160 SCxbus Adapter.


Table 1.  SCX160 Technical Specifications

Max. nodes/system

16

Resource sharing bus

SCbus and SCxbus

Control microprocessor

80C186

HOST INTERFACE:

 

Bus compatibility

IEEE P996 ISA compatible (IBM PC AT)

Bus speed

12.5 MHz maximum

Bus mode

Automatically configures to 8 or 16 bit transfer mode

Shared memory

32 Kbyte page

Base addresses

8000h, on 32K boundaries. All Board Locator Technology (BLT) boards share the same base address. Shared memory is page mapped in/out dynamically as needed.

Interrupt level

IRQ 2/9, 3, 4, 5, 6, 7, 10, 11, 12, 14, 15, software selectable. Only one IRQ line must be shared by all BLT boards.

I/O ports

None

POWER REQUIREMENTS:

+5 VDC
-5 VDC
+12 VDC
-12 VDC

3.40 A max.
0.170 A max.
1.275 A max.
0.255 A max.

Operating temperature

0 _C to +50 _C

Storage temperature

-20 _C to +70 _C

Humidity

5% to 85% non-condensing

Form factor

PC AT, 13.3 in. long, 0.793 in. wide (total envelope), 4.5 in. high (excluding edge connector)

SAFETY & EMI CERTIFICATIONS:

United States

FCC Part 15, Subpart B, Class AUL: 1950 (E96804)

Canada

UL: CSA C22.2 No. 950

European Community

EN55022 Class B

World-Wide

For specific country approval designation, see the Dialogic International Approvals data sheet or contact a Sales Engineer.

Warranty

3 years standard