Previous PageTable Of Contents../index.htmlIndexNext Page


Determining Number of Blocked Data Streams

Before running the Dialogic SCX160 Configuration Program, determine the number of data streams to be blocked in the multi-node system. To determine this number, enter the following information into Table 21.  Dialogic Blocking Configuration Chart and make the indicated calculations:

    1. Repeat procedure from Step 1 for each node.

Table 20.  Time Slots Required Per Board

Board

Resource(s)

Time Slots Required

D/41ESC

Voice
Analog

4
4

D/80SC

Voice

8

D/80SC-4LS

Voice
Analog

8
8

D/160SC

Voice

16

D/160SC-LS

Voice
Analog

16
16

D/240SC

Voice

24

D/240SC-T1

Voice
Digital

24
24

D/240SC-2T1

Voice
Digital

24
48

D/480SC-2T1

Voice
Digital

48
48

D/300SC-E1

Voice
Digital

30
30

D/300SC-2E1

Voice
Digital

30
60

D/320SC

Voice

32

D/600SC-2E1

Voice
Digital

60
60

DCB/320SC

Digital

32

DCB/640SC

Digital

64

DCB/960SC

Digital

96

DTI/240SC

Digital

24

DTI/241SC

Voice
Digital

24
24

DTI/300SC

Digital

30

DTI/301SC

Voice
Digital

30
30

LSI/81SC

Analog
Voice

8
8

LSI/161SC

Analog
Voice

16
16

MSI/80SC

Digital

40

MSI/160SC

Digital

48

MSI/240SC

Digital

56

VFX/40SC

Voice/Fax
Analog

4
4

VFX/40ESC

Voice/Fax
Analog

4
4

VFX/40ESCplus

Voice/Fax
Analog

4
4


Table 21.  Dialogic Blocking Configuration Chart

Node #

Resource Blocked

Boards Installed

Time Slots Blocked

Data Streams Blocked
(Time Slots/64)

         
         
         
         
         
         
         
         
         
         
         
         
         
         
         
         
         
         

Number of data streams to be blocked in EACH node:

 

Table 22.  Example Blocking Configuration Chart

Node #

Resource Blocked

Boards Installed

Time Slots Blocked

Data Streams Blocked(Time Slots/64)

1

Voice

DTI/240SC

0

 
   

D/240SC-T1

24

 
   

D/240SC-T1

24

 
   

D/240SC-T1

24

 
   

D/240SC-T1

24

 
   

D/240SC-T1

24

 
   

Total:

120

2 (120/64 = 1.9)

2

Voice

7 DTI/241SC

24 each

 
   

Total (7 x 24):

168

3 (168/64 = 2.6)

         
         
         
         
         
         
         
         
         

Number of data streams to be blocked in EACH node:

3


Previous PageTable Of ContentsTop Of PageIndexNext Page

Click here to contact Dialogic Customer Engineering

Copyright 2001, Dialogic Corporation
All rights reserved
This page generated February, 2002