version = V1.26-2  1-OCT-2015
#
# This file lists the analysis texts, which show up in the "Analysis" worksheet
# of the output file.
# The syntax per line is as follows:
# <code> <severity> <text>
# <Code> is a 4 digit number
# <Severity> is one of the following: "Informational", "Undetermined",
#                                     "Warning", "Error" and "Critical".
# <Text> is free format text; parameters are enclosed by "%" characters,
#                             such as %p1%
#
# The range    1 -  999 is used for configuration issues.
# The range 1000 - 1999 is used for entries in node logfiles
# The range 2000 - 2999 is used for entries in sysmgr logfiles
# The range 3000 - 3999 is used for entries in showevent log files: nd, al, debug, not config related
# The range 9000 - 9999 is used for unexpected state values
# ----------------------------------------------------------------------------------------
#
   1  Error          Node %p1% does not appear to be active on this array. Please investigate. With the node missing, some findings need to be reviewd keeping this in mind.
   2  Warning        LD %p1% [%p2%] appears to be unowned [%p3%] current state: %p4%, detailed state: %p5%. Please investigate.
   
  10  Warning        Node %p1% is able to communicate to both HBAs of Host "%p2%". Possible Single Point Of Failure.
  11  Warning        HBA %p1% of Host "%p2%" is defined, but not logged in into any hostport. Possible Single Point of Failure.
  12  Warning        Host "%p1%" is defined with only 1 HBA, but has access to %p2% VVs. Possible Single Point of Failure.
  13  Warning        Host "%p1%" has a defined HBA "%p2%", which is not logged into any host port. Possible SAN Configuration issue.
  14  Warning        Host "%p1%" has multiple HBAs accessing the same %p2%".
  15  Warning	     PD%p1% has firmware rev "%p2%", which is not current ("%p3%").
  16  Warning	     Cage%p1% has firmware rev "%p2%", which is not current ("%p3%").
  17  Info           VV "%p1%" has an outstanding SCSI-3 reservation from an unknown host with HBA %p2%.
  18  Error          Host "%p1%" has Virtual Volume "%p2%" presented to it as multiple (%p3%) LUN numbers.
  19  Warning        Virtual Volume "%p1%" presented as multiple (%p2%) LUN numbers to servers. 
  20  Warning        Host "%p1%" has a Port WWN (%p2%) not matching its Node WWN (%p3%).
  21  Error          PD%p1% (Position %p2%) is a 3TB or 4TB drive without being at minimal 3.1.2.MU1+P25, 3.1.2.MU2+P25 or 3.1.2.MU3+P18/P25.
  22  Error          VV "%p1% is listed as member of VVset "%p2%" as well as VVset "%p3%".
  23  Error          PD%p1% requires firmware update. Please install Patch %p2%. See CFI%p3% for more details.
  24  Error          PD%p1% requires corrective action as described for CFI%p2%.
  25  Warning	     Node %p1% is using suspect DIMMs in %p2%. Please replace the DIMM in socket %p3%. See CFI 5134.
  26  Warning	     RCgroup '%p1%' has one or more members presented to %p2% %p3% server(s) (%p4%). This requires "%p5%" policy to be set. See CFI %p6%.  
  27  Warning        PD%p1% requires firmware update. See CFI%p2% for more details.
  28  Warning        CPG '%p1%' has a growth value, which is below the minimum (%p2% nodes -> minimum growth value: %p3%G).
  29  Info           CPG '%p1%' has a growth value, which is different than the default (%p2% nodes -> default growth value: %p3%G).
  30  Warning        Port %p1%, configured as iSCSI port, is configured to use DHCP, while it must have a static IP address.
  31  Warning        PD%p1% requires corrective action by applying "%p2%" if not already applied. See CFI %p3%.
  32  Warning        Port %p1% is configured as "%p2%", while partner port %p3% is configured as "%p4%". Potential Persistent Port issue. 
  33  Info           Node%p1% does not have 100% cache availability (actual: %p2%).
  34  Warning        Approaching limitation on number of host ports (%p1%) within release InFormOS V%p2%. Currently system has %p3% host and %p4% free ports.
  35  Error          Mixture of power supplies not supported in Node Cage with Nodes %p1% and %p2%. PS0 has PartNr %p3%, while PS1 has PartNr %p4%.
  36  Warning        PD%p1% requires corrective action as described in SIE%p2% and BugNr %p3%.
  37  Warning        Port %p1% is configured with "%p2%" being "%p3%". For improved performance during production this setting needs to be "%p4%".
  38  Warning        VV '%p1%' has a reserved snapshot space of %p2%MB, while there are no snapshots related to this VV.Run the "freespace -f %p1%" command to release the %p2%MB.  See CFI 5489.
  39  Critical       VV '%p2%' [%p1%] is provisioned as a TDVV, HP mandates %p3% as the minimum version to support De-Duplication, suggest P18 too. See CFI 6251.
  40  Critical       Periodic RC Copy Group '%p1%' contains a TDVV this requires that the asynchronization period be set to a minimum of 'Period %p2%'. See CFI 6526.
  41  Critical       DDS '%p2%' [%p1%] is showing signs that its GC abandonment percentage of %p3%% is greater than or equal to 50%, this needs to be investigated.
  42  Critical       Found %p1% Dedupe related CPGs; best practices indicate that there should only be %p2% Dedupe CPGs maximum, which equates to %p3% CPGs per node-pair based on %p4% node-pairs. See CFI 6507.
  43  Info           CPG %p1% is supporting both Dedupe VV(s) and NON-DeDupe VV(s)
  44  Critical       Total SSD space utilization is at %p1% and DDS %p2% [%p3%] has only %p4% free space remaining. Please investigate. 
  45  Error          This array is using De-Duplication and has %p1% SSD(s) with an overall utilization of %p2% classified at a severity level of %p3%.
  46  Critical       CPG %p1% is supporting more than 256 TDVVs, which exceeds OS maximums.
  47  Warning	     RCgroup '%p1%' has one or more members presented to %p2% %p3% server(s) (%p4%). If any of these hosts are involved in a CLX configuration the "%p5%" must be DISABLED.  
  48  Critical       CM related Link Errors: refer to CFI 6135 | Node %p1% at %p2% reported %p3%
  49  Error          CM LINK ERRORS: refer to CFI 6135, please investigate | Node %p1% at %p2% reported %p3%
  50  Error          VV %p2% (%p1%) Snap CPG (%p3%) using %p4% devices which are slower than the Base CPG (%p5%) which uses %p6% device. Base and Snap CPGs should be using the same device type, in this case %p6%.
  51  Info           VV %p2% (%p1%) Snap CPG (%p3%) using %p4% devices which are faster and *SMALLER* than the Base CPG (%p5%) which uses %p6% device. Base and Snap CPGs should be using the same device type, in this case %p6%.
  52  Error          VV/SNAPSHOT Name EXCEEDS 31 characters! VV '%p2%' [%p1%] has a name that exceeds 31 characters. See CFI_%p3%.
  53  Critical       King-Cobra Drives detected: PD %p1% is a %p2% and P13 is %p3%. See SAW doc_id: c04700171.
  54  Error          King-Cobra Drive Capacity Failure @ %p6%: PDWWN: %p1% (PDid: %p2% | position: %p3% | model: %p4%) reported %p5% chunklets. See SAW doc_id: c04700171 and investigate.
  55  Error          Drive Capacity Failure @ %p6%: PDWWN: %p1% (PDid: %p2% | position: %p3% | model: %p4%) reported %p5% chunklets. Please Investigate.
  56  Critical       RAID 0 employed with user data! LD: %p1% [ID: %p2%] is configured as RAID 0. RAID 0 provides *NO* data redundancy/protection!
#  57  Error          OPTIMUS ASCEND Drives: Possible Medium Format Corruption issue. PD %p1% [%p2%] with firmware: %p3% may be susceptible to this issue. See CFI 5872, critical information to be reviewed
  58  Error          Host %p1% is connected to Node %p2% only, but has access to %p3% VVs. This is a potential single point of failure.
  59  Warning        Host %p1% with WWN %p2% is mapped to multiple HBAs on the same node, Node %p3% [%p4%].
#  60  Error          OPTIMUS ASCEND FIRMWARE UPGRADE REQUIRED: Upgrade firmware to avoid possible "Medium Format Corruption" issue. PD %p1% [%p2%] with firmware: %p3% is susceptible to this issue. See CFI 5872, critical information to be reviewed.
  61  Error          Port %p1% is a %p2% [%p3%] 16GB HBA with firmware %p4%. See CFI 7839, there is a potential for the array to become unresponsive.
  62  Error          At %p7% Node %p6% reported HAL state [state = %p5%] has stopped responding for port %p1%, a %p2% [%p3%] 16GB HBA with firmware %p4%. See CFI 7839, there is a potential for the array to become unresponsive.
  63  Error          VV %p2% [%p1%], VV ID greater than 32767, this version of OS [%p3%] on this array [SN: %p4%] does not support VV IDs greater than 32767! Please Invesitagte!
  64  Error          OPTIMUS %p4% FIRMWARE UPGRADE REQUIRED: Upgrade firmware to avoid possible "Medium Format Corruption" issue. PD %p1% [%p2%] with firmware: %p3% is susceptible to this issue. Review critical information in CFI_5872 and SAW: http://saw.cce.hp.com/km/saw/view.do?docId=emr_na-c04780380.
  65  Critical       OPTIMUS DISK has experienced the "Medium Format Corruption" issue. PD %p1% [%p2%] with firmware: %p3%. Drive needs to be reformatted. Review CFI_5872 for critical information and SAW: http://saw.cce.hp.com/km/saw/view.do?docId=emr_na-c04780380.
  66  Warning        PD %p1% has a signature from another array, meaning this PD was used in another array. The signature needs to be cleared: try controlpd cryptoerase <WWN>, if a SEAGTE you may need controlpd revert <PSID> <WWN>. Otherwise replace with new disk.
  67  Warning        VV %p2% [%p1%], VV ID greater than 32767, will prevent admission of this VV into an RC group on a target array with HP 3PAR OS version below v3.1.3. See CFI 5819.
  68  Warning        Port %p1% is a %p2% [%p3%] HBA with firmware %p4%. There is a potential for fwcores, leading to stuck IOCTLs, IO's not progressing and ports remaining in "failover pending" state. See CFI 9356.
  69  Warning        Port %p1% is in a "%p2%" state. Corrective action may be required. 
  70  Info           the SA LD %p1% [%p2%] resides on a NL device. Improved performance will be seen when an SA LD uses an FC type PD.
  
  99  Info           %p1% PDs of type %p2% analyzed. %p3% require action. 
  
 101  Warning        Nodepair %p1% has a different number (%p2%) of PDs compared to nodepair %p3% (%p4%).
 102  Warning        Nodepair %p1% has a different number (%p2%) of connected cages compared to nodepair %p3% (%p4%).
 103  Warning        Nodepair %p1% has a different number (%p2%) of %p3% drives compared to nodepair %p4% (%p5%).
 104  Info           Nodepair %p1% serves less than %p2%% [%p3%] of the expected number of LDs (actual: %p4%, expected: %p5%).
 105  Info           Nodepair %p1% serves more than %p2%% [%p3%] of the expected number of LDs (actual: %p4%, expected: %p5%).
 106  Info           Node %p1% serves less than %p2%% [%p3%] of the expected number of LDs (actual: %p4%, expected: %p5%).
 107  Info           Node %p1% serves more than %p2%% [%p3%] of the expected number of LDs (actual: %p4%, expected: %p5%).
 108  Info           Node %p1% serves less than %p2%% [%p3%] of the number of LDs served by its nodepair (actual: %p4%).
 109  Info           Node %p1% serves more than %p2%% [%p3%] of the number of LDs served by its nodepair (actual: %p4%).
 110  Info           Comparing LDs between node-pair members: Node%p1% (%p2% LDs) compared to Node%p3% (%p4% LDs) differ by %p5% LDs, this exceeds an allowed %p7%% (%p6% LDs) error.

 200  Warning        Port %p1% appears to have been experiencing a high number of link down occurrences. %p2%
 201  Warning        PD %p1% appears to be experiencing SAS backend issue per CFI 6582. %p2%
 
 900  Mandatory      Array %p1% is running OS Version 3.2.2.MU1 and REQUIRES that P16 be installed before any type of nodeand/or array restart!
 
1000  Warning        Node %p1% reboot observed at %p3%.
1001  Warning        Node %p1% is unable to join the cluster.
1002  Error          Node %p1% has flusher speed set incorrectly. Use command "/usr/games# cli setmemval kernel%p1% none u32 flusher_speed 0" or refer to SAW document "emr_na-3PAR_2NGJ9C". CFI 3564.
1003  Warning        Node %p1% went through a 'setsysmgr -force_iderecovery'
1004  Warning        Node %p1% reports that Slab memory exceeded the Minor boundaries %p2% times. Refer to "Memory" worksheet
1005  Warning        Node %p1% reports that Slab memory exceeded the Major boundaries %p2% times. Refer to "Memory" worksheet
1006  Warning        Port %p1% is not a valid port type. Observed type: %p2%.
1007  Warning        Node %p1% reports that Swap memory exceeded the Minor boundaries %p2% times. Refer to "Memory" worksheet
1008  Warning        Node %p1% reports that Swap memory exceeded the Major boundaries %p2% times. Refer to "Memory" worksheet
#1009  Error          Node %p1% %p3% panic stack trace: %p4%
1009  Warning        Node %p1% %p3% Call Trace: %p4%
1010  Warning	     Node %p1% is using IPL 5 on HBA%p2%. See CFI 4611.
1011  Critical	     System requires patch %p1%. See CFI%p2%. Reason: %p3%.
1012  Critical	     System requires script '%p1%' to be applied. See CFI%p2%. Reason: %p3%.
1013  Error	         System exhibited issue addressed in new InFormOS release %p1%. See CFI%p2%. Reason: %p3%. 
1014  Error          Node %p1% reports at %p3% an incorrect Node ID set in Eeprom. See CFI 5527.
1015  Warning        Node %p1% is experiencing CPU lock-up events. Software issue.
1016  Warning        Observing high number of '%p1%' events. See CFI%p2%. Reason: %p3%.
1017  Info           The %p1% script has been run on this system on %p2%. See %p3%.
1018  Warning        Observing high Queue Length events. Given that InServ is running %p1% and does not have %p2% installed, and is using %p3%, this potentially is CFI %p4%. Reason: %p5%.
1019  Info           The array appears to be messaging issues involving the fabric ioctl that needs further investigating. %p3%
1020  Error          In %p2% found Node %p1% with a Panic Trace @ %p3%: %p4%
1021  Error          Node %p1% reports one or more T10 DIF errors. 

1050  Warning        Node %p1% has encountered %p2% "Uncorrectable Error in Data Cache Memory" messages, see the "Nodes" tab
 
2000  Info           SYSMGR crash observed node %p1% at %p3%.
2001  Warning	     SYSMGR appears to be unresponsive at %p3% on node %p1%.
2002  Info           SYSMGR startup detected at %p3% on node %p1%.
2003  Warning        SYSMGR reported fwcore at %p3% on node %p1%.
#
#2004  Warning        Node %p1% reports on %p3% that a VV entered the PRESERVED state.  
2004  Warning        Node %p1% reported @ %p2% that VV %p4% [%p3%] was 'Failed Preserved' with a status of %p5%.
2005  Error          Node %p1% reports that data inconsistency is detected: %p4%
2006  Error          Node %p1% detected a slow disk on %p3%. 
2007  Warning        Node %p1% reported that an invalid file is detected.
2008  Error          SYSMGR on node %p1% reports errors writing to Persistent Repository on admin VV at %p3%.
2009  Info           During mounting the filesystem on the admin VV on node %p1%, the filesystem was modified at %p3%.
2010  Warning        Node %p1% experienced errors during accessing either admin or .srdata VV at %p3%.
2011  Error          System is exposed to CFI 6156. Apply 'decrease_rm_mreq_max_visits.sh' and 'decrease_rcopy_cleanup_period.sh' scripts.
2012  Error          Node not integrated into cluster. Occurred at %p3%.
2013  Error          config_lock_tattler is reporting delays which need to be investigated and will have a negative impact on the array. %p1%
2014  Error          Taking too long to acquire a config lock: %p1%
2015  Error          TOC updates taking too long: %p1%
2016  Error          Process event handling has become unresponsive: %p1%

2019  Error          There are %p1% "NEMOE Get" commands with RC_TIMEOUTS encountered in sysmgr logs, this may indicate an issue with NEMOE between nodes. Please investigate.
 
2100  Warning        LD scan reported issues at %p3% on node %p1%.
2101  Warning        Checkld reported issues "%p2%" on node %p1%.
2102  Warning        Checkvv reported issues "%p2%" on node %p1%.
2103  Info           Checkvv reported it fixed issues "%p2%" on node %p1%.

2201  Warning        Rcopy link state change master node %p1%  file %p2%  date %p3%  %p4%
2202  Warning        Rcopy synchronization failed master node %p1%  file %p2%  date %p3%  %p4%
2203  Warning        Rcopy group timeouts master node %p1%  file %p2%  date %p3%  %p4%
2204  Warning        Rcopy handshake events master node %p1%  file %p2%  date %p3%  %p4%
2205  Warning        RC Link check failure observed on node %p1% at %p3%.

3000  Warning        Too many events to process: %p1%
3001  Warning        Unresponsive IOCTL %p1%: %p2%
3002  Info           'subluns' are being created, found %p1% 'createvlun -sublun' commands issued. This is for informational purposes only.
3003  Info           Vendor-specific ASC/ASCQ codes in event logs: PD %p1% [Vendor: %p4% Model: %p5%] Port %p2% on %p3% at %p6% on Node %p10% reported Sense Key: 0x%p7% asc/ascq: 0x%p8%/0x%p9%. These need to be researched further in Vendor docs.
 
9000  Warning        PD%p1% has %p2% failed chunklets.
9002  Warning        PD%p1% not reported on %p2% in cage %p3%.
9003  Warning        PD%p1% not reported active on a loop.
9004  Info           Multiple (%p2%) PDs report they used spare chunklets to hold user chunklets of PD%p1%.
9005  Info           User chunklets of PD%p1% are migrated to other (%p2%) PDs.
9006  Error          PD%p1% active controller is different according to TOC (active: %p2%, TOC: %p3%). 
9007  Error          PD%p1% A-path is different according to TOC (active: %p2%, TOC: %p3%). 
9008  Error          PD%p1% B-path is different according to TOC (active: %p2%, TOC: %p3%).
9009  Error          PD%p1% has both paths disabled: A- %p2% and B - %p3%.
9010  Warning        PD%p1% A-path is disabled: %p2%.
9011  Warning        PD%p1% B-path is disabled: %p2%.
9012  Info           PD WWN %p1%%p2%underwent a crypto-erase @ %p3% on Node %p4%.

9100  Warning        Node%p1% has a high utilization (%p2%%) of filesystem %p3%.
9101  Warning        Node %p1% appears to be in the wrong slot [%p2%] based upon biosbnn data dated %p3%.

9200  Error          SAS cabling incorrect on port %p3%: %p1% (%p4%) not connected to %p2% (%p5%). 

9300  Error          RC Target Policies: The mirror_config policy is currently *disabled* between this array %p1% [%p2%] and the target array %p3% [%p4%]; enable using: setrcopytarget pol mirror_config %p3%           