HPE INTERNAL USE ONLY |
|
Analysis Code: 3003
Severity: Info
INEX is providing this
information for informational purposes only.
Use this information
to help research vendor specific asc/ascq codes that are being reported in the general event
logs from the array.
SEAGATE Vendor Specific Asc/Ascq Codes
Table Note. lists the
Additional Sense (ASC) and
Additional Sense Qualifier (ASCQ) codes. Code
values are
in hexadecimal. ANSI standard SPC-4 lists a more complete table in error description alphabetical order. This Table Note. list adequately covers all Seagate drives,
however.
Note. Table Note. is for reference only, as
not all drives covered by this manual
support all of the codes
listed. Codes without
sense key references may or may
not be supported.
|
ASC (byte 12) |
ASCQ (byte 13) |
Description |
Sense Key |
|
00 |
00 |
No Additional Sense Information |
0 |
|
01 |
00 |
No
Index/Logical Block Signal |
4 |
|
02 |
00 |
No SEEK Complete |
4 |
|
03 |
00 |
Peripheral Device
Write Fault |
1, 3, 4 |
|
03 |
86 |
Write Fault Data Corruption |
|
|
04 |
00 |
Logical
Unit Not Ready, Cause
Not Reportable |
2 |
|
04 |
01 |
Logical
Unit Not Ready, Becoming Ready |
2 |
|
04 |
02 |
Logical
Unit Not Ready, START
UNIT Required |
2 |
|
04 |
03 |
Logical
Unit Not Ready, Manual Intervention Required |
2 |
|
04 |
04 |
Logical Unit Not Ready, Format in Progress |
2 |
|
04 |
09 |
Logical Unit Not
Ready, Self Test
in Progress |
2 |
|
04 |
0A |
Logical
Unit Not Ready, NVC
recovery in progress after and exception event |
2 |
|
04 |
11 |
Logical
Unit Not Ready, Notify
(Enable Spinup) required |
2 |
|
04 |
F0 |
Logical
unit not ready, super certify in progress |
2 |
|
08 |
00 |
Logical Unit Communication
Failure |
9, B |
|
08 |
01 |
Logical
Unit Communication Time-Out |
B |
|
08 |
02 |
Logical Unit Communication
Parity Error |
|
|
09 |
00 |
Track Following Error |
1, 3, 4 |
|
09 |
01 |
Servo Fault |
1, 4 |
|
09 |
04 |
Head Select Fault |
3, 4 |
|
09 |
0D |
Write to at least
one copy of a redundant file failed |
1 |
|
09 |
0E |
Redundant
files have < 50% good
copies |
1 |
|
09 |
F8 |
Calibration
is needed but the QST is set
without the Recal Only bit |
1 |
|
09 |
FF |
Servo Cal completed as part
of self-test |
1 |
|
0A |
00 |
Error Log Overflow |
|
|
0A |
01 |
Failed to write super certify log file |
3 |
|
0A |
02 |
Failed to read super
certify log file |
3 |
|
0B |
00 |
Aborted Command |
B |
|
0B |
01 |
Warning—Specified Temperature Exceeded |
1, 6 |
|
0B |
02 |
Warning, Enclosure Degraded |
1 |
|
ASC (byte 12) |
ASCQ (byte 13) |
Description |
Sense Key |
|
0C |
00 |
Write Error |
3 |
|
0C |
01 |
Write Error Recovered With Auto-Reallocation |
1 |
|
0C |
02 |
Write Error—Auto Reallocation
Failed |
3 |
|
0C |
03 |
Write Error—Recommend Reassignment |
3 |
|
0C |
FF |
Write Error—Too many error recovery revs |
3 |
|
0D |
00 |
Volume Overflow Constants |
D |
|
0E |
00 |
Data Miscompare |
E |
|
10 |
00 |
ID CRC Or ECC Error |
|
|
11 |
00 |
Unrecovered Read Error |
1, 3 |
|
11 |
01 |
Read Retries Exhausted |
|
|
11 |
02 |
Error Too Long To
Correct |
|
|
11 |
04 |
Unrecovered Read Error—Auto Reallocation Failed |
3 |
|
11 |
FF |
Unrecovered Read Error—Too many error recovery revs |
3 |
|
12 |
00 |
Address Mark Not Found For
ID Field |
|
|
12 |
01 |
Recovered Data Without ECC Using Previous Logical Block ID |
|
|
12 |
02 |
Recovered Data With ECC Using Previous Logical Block ID |
|
|
14 |
00 |
Logical Block Not Found |
|
|
14 |
01 |
Record Not Found |
3 |
|
15 |
00 |
Random Positioning Error |
|
|
15 |
01 |
Mechanical Positioning Error |
1, 3, 4 |
|
15 |
02 |
Positioning Error
Detected By Read Of Medium |
|
|
16 |
00 |
Data
Synchronization Mark Error |
1, 3, 4 |
|
17 |
00 |
Recovered Data With No Error Correction Applied |
|
|
17 |
01 |
Recovered Data Using
Retries |
1 |
|
17 |
02 |
Recovered Data Using Positive Offset |
1 |
|
17 |
03 |
Recovered Data Using Negative Offset |
1 |
|
17 |
05 |
Recovered Data Using
Previous Logical Block ID |
|
|
17 |
06 |
Recovered Data Without ECC—Data Auto Reallocated |
|
|
18 |
00 |
Recovered Data With ECC |
1 |
|
18 |
01 |
Recovered Data With ECC And Retries Applied |
1 |
|
18 |
02 |
Recovered
Data With ECC And/Or Retries, Data Auto-Reallocated |
1 |
|
18 |
05 |
Recovered Data—Recommand
Reassignment |
|
|
18 |
06 |
Recovered Data Using ECC and
Offsets |
|
|
18 |
07 |
Recovered Data With ECC—Data Rewritten |
1 |
|
19 |
00 |
Defect List Error |
1, 4 |
|
ASC (byte 12) |
ASCQ (byte 13) |
Description |
Sense Key |
|
19 |
01 |
Defect
List Not Available |
|
|
19 |
02 |
Defect
List Error In Primary
List |
|
|
19 |
03 |
Defect List Error in Grown List |
|
|
19 |
0E |
Fewer than 50% Defect List
Copies |
|
|
1A |
00 |
Parameter List Length
Error |
5 |
|
1B |
00 |
Synchronous Data Transfer Error |
|
|
1C |
00 |
Defect List Not
Found |
1, 4 |
|
1C |
01 |
Primary Defect List Not Found |
|
|
1C |
02 |
Grown Defect List Not Found |
|
|
1C |
83 |
Seagate Unique Diagnostic Code |
|
|
1D |
00 |
Miscompare During Verify Operation |
E |
|
1F |
00 |
Number of Defects Overflows the Allocated Space
That The Read
Defect Command Can
Handle |
1 |
|
20 |
00 |
Invalid Command Operation Code |
5 |
|
20 |
F3 |
Invalid linked command operation
code |
5 |
|
21 |
00 |
Logical Block Address
Out Of Range |
D |
|
24 |
00 |
Invalid Field In CDB |
5 |
|
24 |
01 |
Illegal Queue Type for CDB (Low priority commands must be SIMPLE queue) |
5 |
|
24 |
F0 |
Invalid LBA in linked command |
5 |
|
24 |
F2 |
Invalid linked command operation
code |
5 |
|
24 |
F3 |
Illegal G->P operation request |
5 |
|
25 |
00 |
Logical Unit Not
Supported |
5 |
|
26 |
00 |
Invalid Field In Parameter List |
5 |
|
26 |
01 |
Parameter Not Supported |
5 |
|
26 |
02 |
Parameter Value Invalid |
5 |
|
26 |
03 |
Invalid Field
Parameter—Threshold Parameter |
5 |
|
26 |
04 |
Invalid Release of Active Persistent Reserve |
5 |
|
26 |
05 |
Fail to read valid
log dump data |
5 |
|
26 |
97 |
Invalid Field
Parameter—TMS Firmware Tag |
|
|
26 |
98 |
Invalid Field
Parameter—Check Sum |
|
|
26 |
99 |
Invalid Field
Parameter—Firmware Tag |
|
|
27 |
00 |
Write Protected |
7 |
|
29 |
00 |
Flashing LED occurred |
4 |
|
29 |
00 |
Power On, Reset, Or Bus Device Reset Occurred |
6 |
|
29 |
01 |
Power-On Reset Occurred |
6 |
|
29 |
02 |
SCSI Bus Reset
Occurred |
6 |
|
ASC (byte 12) |
ASCQ (byte 13) |
Description |
Sense Key |
|
29 |
03 |
Bus Device Reset
Function Occurred |
6 |
|
29 |
04 |
Internal Reset Occurred |
6 |
|
29 |
05 |
Transceiver Mode Changed To Single-Ended |
6 |
|
29 |
06 |
Transceiver Mode Changed To LVD |
6 |
|
29 |
07 |
Write Log Dump data to disk successful OR IT Nexus Loss |
6 |
|
29 |
08 |
Write Log Dump data to disk fail |
6 |
|
29 |
09 |
Write Log Dump Entry information fail |
6 |
|
29 |
0A |
Reserved disk space is full |
6 |
|
29 |
0B |
SDBP test service contained an error,
examine status packet(s) for details |
6 |
|
29 |
0C |
SDBP incoming buffer overflow (incoming packet too big) |
6 |
|
29 |
CD |
Flashing LED occurred.
(Cold reset) |
6 |
|
29 |
CE |
Flashing LED occurred. (Warm
reset) |
6 |
|
2A |
01 |
Mode Parameters Changed |
6 |
|
2A |
02 |
Log Parameters Changed |
6 |
|
2A |
03 |
Reservations preempted |
6 |
|
2A |
04 |
Reservations Released |
6 |
|
2A |
05 |
Registrations Preempted |
6 |
|
2C |
00 |
Command Sequence Error |
5 |
|
2F |
00 |
Tagged Commands Cleared By Another Initiator |
6 |
|
31 |
00 |
Medium Format Corrupted |
3 |
|
31 |
01 |
Corruption in R/W format request |
3 |
|
31 |
91 |
Corrupt World Wide Name (WWN) in drive information file |
3 |
|
32 |
00 |
No Defect Spare Location Available |
4 |
|
32 |
01 |
Defect List Update
Error |
3, 4, 5 |
|
32 |
02 |
No Spares Available—Too Many
Defects On One
Track |
|
|
32 |
03 |
Defect list longer
than allocated memory |
3 |
|
33 |
00 |
Flash not ready for access |
3 |
|
35 |
00 |
Unspecified Enclosure Services Failure |
4 |
|
35 |
01 |
Unsupported Enclosure Function |
5 |
|
35 |
02 |
Enclosure Services Unavailable |
2 |
|
35 |
03 |
Enclosure Transfer Failure |
4 |
|
35 |
04 |
Enclosure Transfer Refused |
4 |
|
37 |
00 |
Parameter Rounded |
1 |
|
3D |
00 |
Invalid Bits In Identify Message |
|
|
3E |
03 |
Logical Unit Failed Self Test |
4 |
|
ASC (byte 12) |
ASCQ (byte 13) |
Description |
Sense Key |
|
3E |
00 |
Logical Unit Has
Not Self Configured Yet |
|
|
3F |
00 |
Target Operating Conditions Have Changed |
6 |
|
3F |
01 |
Device internal reset occurred |
6 |
|
3F |
02 |
Changed Operating Definition |
6 |
|
3F |
05 |
Device Identifier Changed |
6 |
|
3F |
0F |
Echo buffer overwritten |
B |
|
3F |
80 |
Buffer contents have changed |
1 |
|
3F |
90 |
Invalid APM Parameters |
|
|
3F |
91 |
World Wide Name (WWN)
Mismatch |
6 |
|
40 |
01 |
DRAM Parity Error |
1, 4 |
|
40 |
02 |
Spinup Error recovered with retries |
1 |
|
42 |
00 |
Power-On Or Self-Test Failure |
4 |
|
42 |
0A |
Port A failed loopback test |
4 |
|
42 |
0B |
Port B failed loopback test |
4 |
|
43 |
00 |
Message Reject Error |
B |
|
44 |
00 |
Internal Target Failure |
1, 3, 4 |
|
44 |
F2 |
Data Integrity Check Failed on verify |
4 |
|
44 |
F6 |
Data Integrity Check Failed during write |
4 |
|
44 |
FF |
XOR CDB check error |
4 |
|
45 |
00 |
Select/Reselection Failure |
B |
|
47 |
00 |
SCSI Parity Error |
B |
|
47 |
03 |
Information Unit CRC
Error |
B |
|
47 |
80 |
Fibre Channel Sequence Error |
B |
|
48 |
00 |
Initiator Detected Error Message Received |
B |
|
49 |
00 |
Invalid Message Received |
B |
|
4B |
00 |
Data Phase Error |
B |
|
4B |
01 |
Invalid transfer tag |
B |
|
4B |
02 |
Too many write data |
B |
|
4B |
03 |
ACK NAK Timeout |
B |
|
4B |
04 |
NAK received |
B |
|
4B |
05 |
Data Offset error |
B |
|
4B |
06 |
Initiator response timeout |
B |
|
4C |
00 |
Logical Unit Failed Self-Configuration |
|
|
4E |
00 |
Overlapped Commands Attempted |
B |
|
55 |
01 |
XOR Cache is Not Available |
|
|
55 |
04 |
PRKT table is full |
5 |
|
5B1 |
00 |
Log Exception |
|
|
5B* |
01 |
Threshold Condition
Met |
|
|
5B* |
02 |
Log
Counter At Maximum |
|
|
5B* |
03 |
Log List Codes
Exhausted |
|
|
5C |
00 |
RPL Status Change |
6 |
|
5C |
01 |
Spindles Synchronized |
|
|
5C |
02 |
Spindles Not Synchronized |
|
|
5D |
00 |
Failure Prediction Threshold Exceeded |
1, 6 |
|
5D |
FF |
False Failure Prediction Threshold Exceeded |
1, 6 |
|
65 |
00 |
Voltage Fault |
4 |
|
80 |
00 |
General Firmware Error Qualifier |
9 |
|
80 |
86 |
IOEDC Error on Read |
9 |
|
80 |
87 |
IOEDC Error on Write |
9 |
|
80 |
88 |
Host Parity Check Failed |
9 |
|
80 |
89 |
IOEDC Error on Read Detected by Formatter |
9 |
|
80 |
8A |
Host FIFO Parity Error
detected by Common Buffer |
9 |
|
80 |
8B |
Host FIFO Parity
Error detected by frame buffer
logic |
9 |
|
80 |
8C |
Host Data
Frame Buffer
Parity Error |
9 |
|
81 |
00 |
Reassign
Power—Fail Recovery Failed |
|
|
81 |
00 |
LA Check Error, LCM
bit = 0 |
4 |
|
81 |
00 |
LA Check Error |
B |
|
B4 |
00 |
Unreported Deferred Errors have been logged on
log page 34h |
6 |
[1] Can be supported, but is
a factory installed option.