HPE

INTERNAL USE ONLY

Image result for HP new logo

 

 

Analysis Code: 3003

Severity: Info

 

INEX is providing this information for informational purposes only.

 

Use this information to help research vendor specific asc/ascq codes that are being reported in the general event logs from the array.

 

SEAGATE Vendor Specific Asc/Ascq Codes

 


 

 

SEAGATE Specific Vendor Codes

Table Note. lists the Additional Sense (ASC) and Additional Sense Qualifier (ASCQ) codes. Code values are in hexadecimal. ANSI standard SPC-4 lists a more complete table in error description alphabetical order. This Table Note. list adequately covers all Seagate drives, however.

Note.      Table Note. is for reference only, as not all drives covered by this manual support all of the codes listed. Codes without sense key references may or may not be supported.

 

Table 29        Additional Sense and Additional Sense Qualifier codes

 

ASC

(byte 12)

ASCQ

(byte 13)

Description

Sense Key

00

00

No Additional Sense Information

0

01

00

No Index/Logical Block Signal

4

02

00

No SEEK Complete

4

03

00

Peripheral Device Write Fault

1, 3, 4

03

86

Write Fault Data Corruption

 

04

00

Logical Unit Not Ready, Cause Not Reportable

2

04

01

Logical Unit Not Ready, Becoming Ready

2

04

02

Logical Unit Not Ready, START UNIT Required

2

04

03

Logical Unit Not Ready, Manual Intervention Required

2

04

04

Logical Unit Not Ready, Format in Progress

2

04

09

Logical Unit Not Ready, Self Test in Progress

2

04

0A

Logical Unit Not Ready, NVC recovery in progress after and exception event

2

04

11

Logical Unit Not Ready, Notify (Enable Spinup) required

2

04

F0

Logical unit not ready, super certify in progress

2

08

00

Logical Unit Communication Failure

9, B

08

01

Logical Unit Communication Time-Out

B

08

02

Logical Unit Communication Parity Error

 

09

00

Track Following Error

1, 3, 4

09

01

Servo Fault

1, 4

09

04

Head Select Fault

3, 4

09

0D

Write to at least one copy of a redundant file failed

1

09

0E

Redundant files have < 50% good copies

1

09

F8

Calibration is needed but the QST is set without the Recal Only bit

1

09

FF

Servo Cal completed as part of self-test

1

0A

00

Error Log Overflow

 

0A

01

Failed to write super certify log file

3

0A

02

Failed to read super certify log file

3

0B

00

Aborted Command

B

0B

01

Warning—Specified Temperature Exceeded

1, 6

0B

02

Warning, Enclosure Degraded

1


 

ASC

(byte 12)

ASCQ

(byte 13)

Description

Sense Key

0C

00

Write Error

3

0C

01

Write Error Recovered With Auto-Reallocation

1

0C

02

Write Error—Auto Reallocation Failed

3

0C

03

Write Error—Recommend Reassignment

3

0C

FF

Write Error—Too many error recovery revs

3

0D

00

Volume Overflow Constants

D

0E

00

Data Miscompare

E

10

00

ID CRC Or ECC Error

 

11

00

Unrecovered Read Error

1, 3

11

01

Read Retries Exhausted

 

11

02

Error Too Long To Correct

 

11

04

Unrecovered Read Error—Auto Reallocation Failed

3

11

FF

Unrecovered Read Error—Too many error recovery revs

3

12

00

Address Mark Not Found For ID Field

 

12

01

Recovered Data Without ECC Using Previous Logical Block ID

 

12

02

Recovered Data With ECC Using Previous Logical Block ID

 

14

00

Logical Block Not Found

 

14

01

Record Not Found

3

15

00

Random Positioning Error

 

15

01

Mechanical Positioning Error

1, 3, 4

15

02

Positioning Error Detected By Read Of Medium

 

16

00

Data Synchronization Mark Error

1, 3, 4

17

00

Recovered Data With No Error Correction Applied

 

17

01

Recovered Data Using Retries

1

17

02

Recovered Data Using Positive Offset

1

17

03

Recovered Data Using Negative Offset

1

17

05

Recovered Data Using Previous Logical Block ID

 

17

06

Recovered Data Without ECC—Data Auto Reallocated

 

18

00

Recovered Data With ECC

1

18

01

Recovered Data With ECC And Retries Applied

1

18

02

Recovered Data With ECC And/Or Retries, Data Auto-Reallocated

1

18

05

Recovered Data—Recommand Reassignment

 

18

06

Recovered Data Using ECC and Offsets

 

18

07

Recovered Data With ECC—Data Rewritten

1

19

00

Defect List Error

1, 4


 

ASC

(byte 12)

ASCQ

(byte 13)

Description

Sense Key

19

01

Defect List Not Available

 

19

02

Defect List Error In Primary List

 

19

03

Defect List Error in Grown List

 

19

0E

Fewer than 50% Defect List Copies

 

1A

00

Parameter List Length Error

5

1B

00

Synchronous Data Transfer Error

 

1C

00

Defect List Not Found

1, 4

1C

01

Primary Defect List Not Found

 

1C

02

Grown Defect List Not Found

 

1C

83

Seagate Unique Diagnostic Code

 

1D

00

Miscompare During Verify Operation

E

1F

00

Number of Defects Overflows the Allocated Space That The Read Defect Command Can Handle

1

20

00

Invalid Command Operation Code

5

20

F3

Invalid linked command operation code

5

21

00

Logical Block Address Out Of Range

D

24

00

Invalid Field In CDB

5

24

01

Illegal Queue Type for CDB (Low priority commands must be SIMPLE queue)

5

24

F0

Invalid LBA in linked command

5

24

F2

Invalid linked command operation code

5

24

F3

Illegal G->P operation request

5

25

00

Logical Unit Not Supported

5

26

00

Invalid Field In Parameter List

5

26

01

Parameter Not Supported

5

26

02

Parameter Value Invalid

5

26

03

Invalid Field Parameter—Threshold Parameter

5

26

04

Invalid Release of Active Persistent Reserve

5

26

05

Fail to read valid log dump data

5

26

97

Invalid Field Parameter—TMS Firmware Tag

 

26

98

Invalid Field Parameter—Check Sum

 

26

99

Invalid Field Parameter—Firmware Tag

 

27

00

Write Protected

7

29

00

Flashing LED occurred

4

29

00

Power On, Reset, Or Bus Device Reset Occurred

6

29

01

Power-On Reset Occurred

6

29

02

SCSI Bus Reset Occurred

6


 

ASC

(byte 12)

ASCQ

(byte 13)

Description

Sense Key

29

03

Bus Device Reset Function Occurred

6

29

04

Internal Reset Occurred

6

29

05

Transceiver Mode Changed To Single-Ended

6

29

06

Transceiver Mode Changed To LVD

6

29

07

Write Log Dump data to disk successful OR IT Nexus Loss

6

29

08

Write Log Dump data to disk fail

6

29

09

Write Log Dump Entry information fail

6

29

0A

Reserved disk space is full

6

29

0B

SDBP test service contained an error, examine status packet(s) for details

6

29

0C

SDBP incoming buffer overflow (incoming packet too big)

6

29

CD

Flashing LED occurred. (Cold reset)

6

29

CE

Flashing LED occurred. (Warm reset)

6

2A

01

Mode Parameters Changed

6

2A

02

Log Parameters Changed

6

2A

03

Reservations preempted

6

2A

04

Reservations Released

6

2A

05

Registrations Preempted

6

2C

00

Command Sequence Error

5

2F

00

Tagged Commands Cleared By Another Initiator

6

31

00

Medium Format Corrupted

3

31

01

Corruption in R/W format request

3

31

91

Corrupt World Wide Name (WWN) in drive information file

3

32

00

No Defect Spare Location Available

4

32

01

Defect List Update Error

3, 4, 5

32

02

No Spares Available—Too Many Defects On One Track

 

32

03

Defect list longer than allocated memory

3

33

00

Flash not ready for access

3

35

00

Unspecified Enclosure Services Failure

4

35

01

Unsupported Enclosure Function

5

35

02

Enclosure Services Unavailable

2

35

03

Enclosure Transfer Failure

4

35

04

Enclosure Transfer Refused

4

37

00

Parameter Rounded

1

3D

00

Invalid Bits In Identify Message

 

3E

03

Logical Unit Failed Self Test

4


 

ASC

(byte 12)

ASCQ

(byte 13)

Description

Sense Key

3E

00

Logical Unit Has Not Self Configured Yet

 

3F

00

Target Operating Conditions Have Changed

6

3F

01

Device internal reset occurred

6

3F

02

Changed Operating Definition

6

3F

05

Device Identifier Changed

6

3F

0F

Echo buffer overwritten

B

3F

80

Buffer contents have changed

1

3F

90

Invalid APM Parameters

 

3F

91

World Wide Name (WWN) Mismatch

6

40

01

DRAM Parity Error

1, 4

40

02

Spinup Error recovered with retries

1

42

00

Power-On Or Self-Test Failure

4

42

0A

Port A failed loopback test

4

42

0B

Port B failed loopback test

4

43

00

Message Reject Error

B

44

00

Internal Target Failure

1, 3, 4

44

F2

Data Integrity Check Failed on verify

4

44

F6

Data Integrity Check Failed during write

4

44

FF

XOR CDB check error

4

45

00

Select/Reselection Failure

B

47

00

SCSI Parity Error

B

47

03

Information Unit CRC Error

B

47

80

Fibre Channel Sequence Error

B

48

00

Initiator Detected Error Message Received

B

49

00

Invalid Message Received

B

4B

00

Data Phase Error

B

4B

01

Invalid transfer tag

B

4B

02

Too many write data

B

4B

03

ACK NAK Timeout

B

4B

04

NAK received

B

4B

05

Data Offset error

B

4B

06

Initiator response timeout

B

4C

00

Logical Unit Failed Self-Configuration

 

4E

00

Overlapped Commands Attempted

B

55

01

XOR Cache is Not Available

 


 

55

04

PRKT table is full

5

5B1

00

Log Exception

 

5B*

01

Threshold Condition Met

 

5B*

02

Log Counter At Maximum

 

5B*

03

Log List Codes Exhausted

 

5C

00

RPL Status Change

6

5C

01

Spindles Synchronized

 

5C

02

Spindles Not Synchronized

 

5D

00

Failure Prediction Threshold Exceeded

1, 6

5D

FF

False Failure Prediction Threshold Exceeded

1, 6

65

00

Voltage Fault

4

80

00

General Firmware Error Qualifier

9

80

86

IOEDC Error on Read

9

80

87

IOEDC Error on Write

9

80

88

Host Parity Check Failed

9

80

89

IOEDC Error on Read Detected by Formatter

9

80

8A

Host FIFO Parity Error detected by Common Buffer

9

80

8B

Host FIFO Parity Error detected by frame buffer logic

9

80

8C

Host Data Frame Buffer Parity Error

9

81

00

Reassign Power—Fail Recovery Failed

 

81

00

LA Check Error, LCM bit = 0

4

81

00

LA Check Error

B

B4

00

Unreported Deferred Errors have been logged on log page 34h

6

 

[1]       Can be supported, but is a factory installed option.