Powering off the UR secondary storage system

Use the following procedure to power off the UR secondary storage system in a GAD 3DC delta resync environment.

Procedure

  1. On the primary storage system, suspend the UR pairs by specifying the P-VOL.

    Command example: pairsplit -g oraREMOTE -IH0
  2. Confirm that the pair statuses are changed as shown in the following table.

    Pair type

    Before the GAD pair suspension

    After the GAD pair suspension

    P-VOL

    S-VOL

    P-VOL

    S-VOL

    GAD pair

    PAIR (Mirror(RL))

    PAIR (Mirror(RL))

    PAIR (Mirror(RL))

    PAIR (Mirror(RL))

    UR pair

    PAIR

    PAIR

    PSUS

    PSUS

    UR delta resync pair

    PSUS1

    SSUS1

    PSUE2

    SSUS1

    Notes:

    1. Device Manager - Storage Navigator displays HOLD.
    2. Device Manager - Storage Navigator displays HOLDING.
  3. Power off the UR secondary storage system.