Cache capacity with capacity saving-enabled
DP-VOLs
The following tables show the recommended cache capacity when all volumes in the storage system have capacity saving enabled (simplest case).
|
Total capacity of DRD-VOLs* (Effective Capacity) |
Recommended cache capacity (each CLPR) | |||
| VSP G200 | VSP G400 | VSP G600 | VSP G800 | |
| Less than 4TiB | 28GiB | 28GiB | 28GiB | 28GiB |
| 4TiB or more | 20GiB+X | 20GiB+X | 20GiB+X | 20GiB+X |
| 7.5TiB or more | 35GiB | 20GiB+X | 20GiB+X | 20GiB+X |
| 16TiB or more | 24GiB+X | 24GiB+X | 24GiB+X | |
| 31TiB or more | 86GiB | 24GiB+X | 24GiB+X | |
| 48TiB or more | 32GiB+X | 32GiB+X | ||
| 90.5TiB or more | 213GiB | 32GiB+X | ||
| 96TiB or more | 40GiB+X | |||
| 160TiB or more | 48GiB+X | |||
| 201.5TiB or more | 451GiB | |||
| X is the total capacity of DRD-VOLs x 0.2%
* DRD-VOL: data reduction volume, which is a DP-VOL with capacity saving enabled. | ||||