Edit Mirror Options window

Use this window to change a mirror’s options.

For instructions, in the Help Contents tab, click: Maintaining the UR system Journal and mirror maintenance Changing options used by mirrors

Item

Description

Path Watch Time

Interval from the time a path becomes blocked to the time when the mirror is suspended.

The Path Watch Time value can be specified using Minutes, Hours, or Days. The range is 1 to 59 minutes, 1 to 23 hours, or 1 to 30 days.

Path Watch Time Transfer

Indicates whether to transfer the master journal's Path Watch Time value to the mirror's secondary side (RCU). When transferred, the Path Watch Time values of the mirror's primary side (MCU) and the secondary side (RCU) will be consistent.

  • Yes: Path Watch Time value will be transferred to the mirror's secondary side (RCU).
  • No: Path Watch Time value will not be transferred to the mirror's secondary side (RCU). Default value is No.

Copy Pace

Pace for copying data during initial copy: Slower is the default, Medium, Faster.

Transfer Speed

Data transfer line speed in Mbps (megabits per second): 3, 10, 100, or 256.

Delta Resync Failure

Processing that takes place in the event of delta resync operation failure.

  • Entire Copy: The entire P-VOL is copied to the S-VOL.
  • No Copy: No processing occurs. The S-VOL is not updated.

Delta Resync Failure cannot be set at the secondary site. Use Entire Copy if your journals are part of a multiple-journal configuration in a CCI consistency group.

When you use UR with GAD, NO COPY applies regardless of the setting. If delta resync processing fails, no processing is performed and the S-VOL is not updated. In that case, resync the UR pair.