Monitoring failure information in the Windows event log
You can manage the Windows error information by outputting failure information to the event log.
Before you begin
- The storage system status in the storage device list must be READY.
Procedure
Open a Windows command prompt with administrator permissions in SVP.
Execute the following command to move the current directory:
cd /d C:\Mapp\wk\model-identification-number\DKC200\mp\pc
- The default installation directory is
C:\Mapp:<installation-directory-of-SVP>NoteC:\Mappindicates the installation directory of Device Manager - Storage Navigator. If you specified another directory, replaceC:\Mapp:with the specified installation directory.- Without moving the current directory, failure information is not output to the Windows event log if you execute the batch file in step 3.
-
model-identification-number: Use the format
83<model-name><serial-number>, where <model-name> is one of the following:VSP G200: 2000
VSP G400 or VSP F400, VSP G600 or VSP F600: 4000
VSP G800 or VSP F800: 6000
For example, for a VSP G600 that has the serial number 400102, the value is
834000400102.
- The default installation directory is
Execute the following batch file:
eventlog.bat action monitoring-period
-
action: Specify one of the following:
0: Stop outputting failure information
1: Start outputting failure information
when this parameter is omitted, 0 is set.
-
monitoring-period: If you specified 1 for action, specify the monitoring period, from 5 to 720 minutes.
- A space is required between
eventlog.batand action. - A space is required between action and monitoring-period.
- The command prompt is displayed if the command finishes without any errors.
-
Close the command prompt.