Delta resync configuration

With the delta resync configuration, you bring the S-VOL to a consistent state more quickly after failure because only missing differential data must be copied.

You create the delta resync configuration by adding a second UR pair to the 3DC multi-target configuration, using the TC S-VOL and the UR S-VOL, as illustrated in the following figure. The delta resync operation is performed when the primary site fails.

Procedure

  1. Create the UR delta resync pair. See Creating the delta resync pair.
  2. Set up and map remote command devices and external ports in each site. With remote command devices, sites automatically connect with each other. See Setting up remote command devices for use with RAID Manager.
  3. Assign mirror IDs to remote command devices. See Assigning mirrors to remote command devices for delta resync operations.
  4. In a recovery situation, run the delta resync operation. See Performing the delta resync operation.