Requirements for increasing DP-VOL capacity

To notify the host that the DP-VOL capacity has been increased, make sure host mode option 40 is enabled. Processing differs as follows, depending on the value of host mode option 40:

  • When host mode option 40 is not enabled, the host will not be notified that the DP-VOL capacity has been increased. Therefore, the DP-VOL data has to be read again by the host after the capacity is increased.
  • When host mode option 40 is enabled, the host is notified that the DP-VOL capacity has increased. If the operating system cannot recognize the value of capacity that was increased, the DP-VOL data has to be read again by your storage system.

The following requirements are important when increasing the DP-VOL capacity:

  • The DP-VOL to be increased is not shared with a software product that does not allow increasing the volume capacity (see Increasing DP-VOL capacity).
  • The DP-VOL is not undergoing LDEV formatting.
  • The DP-VOL does not have data direct mapping enabled.
  • The DP-VOL is not a deduplication system data volume.
  • The capacity to be added to the DP-VOL must be specified within the range indicated below LDEV Capacity in the Expand V-VOLs window.
  • The pool related to the DP-VOLs to be increased is in any one of the following statuses:
    • Normal
    • Exceeding the subscription limit threshold
    • In progress of pool capacity shrinking
CautionWhen increasing DP-VOL capacity, do not perform the following operations. When you perform these operations, do not increase DP-VOL capacity.
  • Operations using Virtual LUN
  • Creating DP-VOLs
  • Restoring pools
  • Deleting DP-VOLs
  • Operations to increase the DP-VOL capacity in another instance of RAID Manager
  • Maintenance of your storage system

After increasing DP-VOL capacity, refresh the display and confirm that the DP-VOL is increased. If the DP-VOL capacity is not increased, wait a while, refresh the display again, and confirm that the DP-VOL is increased. If you perform an operation without making sure that the DP-VOL is increased, operations from Device Manager - Storage Navigator may fail.

If one of the following operations is being performed, the DP-VOL capacity might not be increased:

  • Volume Migration
  • Configuration change of journal used by Universal Replicator
  • Quick Restore by ShadowImage