Prerequisites for 3DC cascade
- One
VSP G800,
VSP F800,
VSP G1000,
VSP G1500, or
VSP F1500 is required for each site.
HUS VM is not supported in 3DC cascade configurations.
- If a site has multiple storage system, 3DC cascade cannot be configured.
-
RAID Manager
is recommended at all the sites.
- Device Manager - Storage Navigator is required at all sites.
- The primary site requires the following:
- Host application
-
TC
- TC primary volume (P-VOL), the primary production volume
- The
TC P-VOL fence level (Primary Volume Fence Level) must be
Secondary Volume Data.
- The intermediate site requires the following:
-
TC
-
UR
- TC S-VOL =
UR P-VOL
- UR master journal volume
- The secondary site requires the following:
-
UR
- UR S-VOL
- UR restore journal volume
- Differential data is used to resynchronize a suspended
TC or
UR pair.
- When the
TC pair is resynchronized, the
UR pair in
PAIR or
COPY status is automatically split by the system.