RAID Manager mirror status definitions

RAID Manager mirror statuses appear beside Device Manager - Storage Navigator statuses in the HDvM - SN/RAID Manager format. The following describe RAID Manager statuses.

Status

Description

SMPL

The mirror is not used.

PJNN

The master journal is normal.

SJNN

The restore journal is normal.

PJSN

The master journal is in normal split status.

SJSN

The restore journal is in normal split status.

PJNS

The master journal is in normal split status (delta resync configuration).

SJNS

The restore journal is in normal split status (delta resync configuration).

PJNF

The master journal is full.

SJNF

The restore journal is full.

PJSF

The master journal is full and split.

SJSF

The restore journal is full and split.

PJSE

The master journal is split due to an error (including link errors).

SJSE

The restore journal is split due to an error (including link errors).

PJES

The master journal is in split status (delta resync configuration) due to an error.

SJES

The restore journal is in split status (delta resync configuration) due to an error.