Monitor Performance window
Use this window to specify the monitoring period and monitoring objects that will be displayed in graphs. You can set a maximum of eight monitoring objects per graph panel. You can set a maximum of four graph panels with up to 16 monitoring objects.
Data Range
Specify a range of statistics. Short-Range is default when there is monitor data collected with short range. However, Long-Range is default when there is no monitor data collected with short range.
- Short-Range: Graphs are displayed according to the value specified in the Sample Interval field in the Edit Monitoring Switch window. You can specify the sampling interval from 1 to 15 minutes. The interval for measuring or storing the information depends on the number of CUs to be monitored.
- Long-Range: Graphs are displayed 0, 15, 30, or 45 minutes on every hour.
Time Range
Specify the storing period of statistics
- Set Range: Select this option to specify start and ending times to set a time range for which monitoring statistics will be collected.
- Use Real Time: Select this option to view statistics in real time mode, where statistics are updated at the value of the Sample Interval you specify on the Edit Monitoring Switch window. This option is available when the Short-Range mode is selected. When this option is selected, you cannot change the date field in the Set Range option.
Performance Objects
|
Item |
Description |
|
Object |
Types of objects to display on graphs. The list on the left specifies a large classification of monitoring objects. The list on the right specifies a small classification of monitoring objects. |
|
Monitor Data |
Performance data specified in the field. The list on the left specifies a large classification of performance data. The list on the right specifies a small classification of performance data. For details, see Object and Monitor Data combinations. |
|
Performance Object Selection |
Objects that can be displayed in graphs. For details, see Available Objects table. |
Add
Adds objects to display the graph.
Selected Objects table
|
Item |
Description |
|
Object |
Object types selected in the Performance Objects area. |
|
Monitor Data |
Monitor data types selected in the Performance Objects area. |
|
Object ID |
IDs of the selected objects. |
|
Remove |
Selected rows can be deleted from the table. |
Object and Monitor Data combinations
The following table shows the possible Object and Monitor Data combinations that can be selected in the Performance Objects area of the Monitor Performance window.
- If Controller is selected on the left side of the Object field, the item on the right side of Monitor Data field is blank.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
MP |
Usage Rate |
% |
- If Cache is selected on the left side of the Object field, items on the right side of the Object and Monitor Data is blank field.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
None |
Usage Rate |
% |
|
None |
Write Pending Rate |
% |
- If Fibre Port is selected on the left side of the Object field, the item on the right side of the Monitor Data field is blank.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
Target |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Response Time |
ms | |
|
Initiator |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Response Time |
ms |
- If iSCSI Port is selected on the left side of the Object field, the item on right side of the Monitor Data field is blank.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
Target |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Response Time |
ms | |
|
Initiator |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Response Time |
ms |
- If NAS Platform (User LU) or NAS Platform (System LU) is selected on the left side of the Object field, the item on the right side of the Monitor Data field is blank.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
Target |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Response Time |
ms |
- If WWN is selected on the left side of the Object field, the item on the right side of the Monitor Data field is blank.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
WWN |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Response Time |
ms | |
|
Port |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Response Time |
ms |
- If Logical Device is selected on the left side of the Object field and if Base is selected on the right of the Object field, the following items can be selected.
|
Item on left side of Monitor Data field |
Item on right side of Monitor Data field |
Unit of monitoring data |
|
Total Throughput |
Total |
IOPS |
|
Sequential | ||
|
Random | ||
|
CFW | ||
|
Read Throughput |
Total |
IOPS |
|
Sequential | ||
|
Random | ||
|
CFW | ||
|
Write Throughput |
Total |
IOPS |
|
Sequential | ||
|
Random | ||
|
CFW | ||
|
Cache Hit |
Read (Total) |
% |
|
Read (Sequential) | ||
|
Read (Random) | ||
|
Read (CFW) | ||
|
Write (Total) | ||
|
Write (Sequential) | ||
|
Write (Random) | ||
|
Write (CFW) | ||
|
Data Trans. |
Total |
MB/s |
|
Read | ||
|
Write | ||
|
Response Time |
Total |
ms |
|
Read | ||
|
Write | ||
|
Back Trans. |
Total |
count/sec |
|
Cache To Drive | ||
|
Drive To Cache (Sequential) | ||
|
Drive To Cache (Random) | ||
|
Drive Usage Rate1 |
None |
% |
|
Drive Access Rate1 |
Read (Sequential) |
% |
|
Read (Random) | ||
|
Write (Sequential) | ||
|
Write (Random) | ||
|
ShadowImage1,2 |
None |
% |
|
Notes:
| ||
- If Logical Device is selected on the left side of the Object field and if TC/TCMF/GAD is selected on the right side of the Object field, the following items can be selected.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
RIO |
Total |
count |
|
Write | ||
|
Error | ||
|
Pair Synchronization Rate |
None |
% |
|
Differential Track |
None |
count |
|
Initial Copy |
Throughput |
count |
|
Data Trans. |
MB/s | |
|
Response Time |
ms | |
|
Update Copy |
Throughput |
count |
|
Data Trans. |
MB/s | |
|
Response Time |
ms |
- If Logical Device is selected on the left side of the Object field and if UR/URMF is selected on the right side of the Object field, the following items can be selected.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
Write Host I/O |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Initial Copy |
Cache Hit |
% |
|
Data Trans. |
MB/s |
- If Parity Group is selected on the left side of the Object field, the item on the right side of the Object field is blank. A parity group is displayed only when the CU number of each LDEV within the parity group is to be monitored.
|
Item on left side of Monitor Data field |
Item on right side of Monitor Data field |
Unit of monitoring data |
|
Total Throughput |
Total |
IOPS |
|
Sequential | ||
|
Random | ||
|
CFW | ||
|
Read Throughput |
Total |
IOPS |
|
Sequential | ||
|
Random | ||
|
CFW | ||
|
Write Throughput |
Total |
IOPS |
|
Sequential | ||
|
Random | ||
|
CFW | ||
|
Cache Hit |
Read (Total) |
% |
|
Read (Sequential) | ||
|
Read (Random) | ||
|
Read (CFW) | ||
|
Write (Total) | ||
|
Write (Sequential) | ||
|
Write (Random) | ||
|
Write (CFW) | ||
|
Data Trans. |
Total |
MB/s |
|
Read | ||
|
Write | ||
|
Response Time |
Total |
ms |
|
Read | ||
|
Write | ||
|
Back Trans. |
Total |
count/sec |
|
Cache To Drive | ||
|
Drive To Cache (Sequential) | ||
|
Drive To Cache (Random) | ||
|
Drive Usage Rate* |
None |
% |
|
* Only information about internal volumes is displayed. Information about the following is not displayed:
| ||
- If LUN is selected on the left side of the Object field and if Base is selected on the right of the Object field, the following items can be selected.
|
Item on left side of Monitor Data field |
Item on right side of Monitor Data field |
Unit of monitoring data |
|
Total Throughput |
Total |
IOPS |
|
Sequential | ||
|
Random | ||
|
CFW | ||
|
Read Throughput |
Total |
IOPS |
|
Sequential | ||
|
Random | ||
|
CFW | ||
|
Write Throughput |
Total |
IOPS |
|
Sequential | ||
|
Random | ||
|
CFW | ||
|
Cache Hit |
Read (Total) |
% |
|
Read (Sequential) | ||
|
Read (Random) | ||
|
Read (CFW) | ||
|
Write (Total) | ||
|
Write (Sequential) | ||
|
Write (Random) | ||
|
Write (CFW) | ||
|
Data Trans. |
Total |
MB/s |
|
Read | ||
|
Write | ||
|
Response Time |
Total |
ms |
|
Read | ||
|
Write | ||
|
Back Trans. |
Total |
count/sec |
|
Cache To Drive | ||
|
Drive To Cache (Sequential) | ||
|
Drive To Cache (Random) |
- If LUN is selected on the left side of the Object field and if TC/GAD is selected on the right of the Object field, the following items can be selected.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
RIO |
Total |
count |
|
Write | ||
|
Error | ||
|
Pair Synchronization Rate |
None |
% |
|
Differential Track |
None |
count |
|
Initial Copy |
Throughput |
count |
|
Data Trans. |
MB/s | |
|
Response Time |
ms | |
|
Update Copy |
Throughput |
count |
|
Data Trans. |
MB/s | |
|
Response Time |
ms |
- If LUN is selected on the left side of the Object field and if UR is selected on the right of the Object field, the following items can be selected.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
Write Host I/O |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Initial Copy |
Cache Hit |
% |
|
Data Trans. |
MB/s |
- If Journal is selected on the left side of the Object field, UR/URMF is selected on the right side of the Object field.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
Write Host I/O |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Initial Copy |
Cache Hit |
% |
|
Data Trans. |
MB/s | |
|
Master Journal |
Throughput |
IOPS |
|
Journal |
count/sec | |
|
Data Trans. |
MB/s | |
|
Response Time |
ms | |
|
Data Usage Rate |
% | |
|
Meta Data Usage Rate |
% | |
|
Restore Journal |
Throughput |
IOPS |
|
Journal |
count/sec | |
|
Data Trans. |
MB/s | |
|
Response Time |
ms | |
|
Data Usage Rate |
% | |
|
Meta Data Usage Rate |
% |
- If Entire Storage System is selected on the left side of the Object field and if TC/TC-MF/GAD is selected on the right side of the Object field, the following items can be selected.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
RIO |
Total |
count |
|
Write | ||
|
Error | ||
|
Pair Synchronization Rate |
None |
% |
|
Differential Track |
None |
count |
|
Initial Copy |
Throughput |
count |
|
Data Trans. |
MB/s | |
|
Response Time |
ms | |
|
Update Copy |
Throughput |
count |
|
Data Trans. |
MB/s | |
|
Response Time |
ms |
- If Entire Storage System is selected on the left side of the Object field and if UR/UR-MF is selected on the right side of the Object field, the following items can be selected.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Unit of monitoring data |
|
Write Host I/O |
Throughput |
IOPS |
|
Data Trans. |
MB/s | |
|
Initial Copy |
Cache Hit |
% |
|
Data Trans. |
MB/s | |
|
Master Journal |
Throughput |
IOPS |
|
Journal |
count/sec | |
|
Data Trans. |
MB/s | |
|
Response Time |
ms | |
|
Restore Journal |
Throughput |
IOPS |
|
Journal |
count/sec | |
|
Data Trans. |
MB/s | |
|
Response Time |
ms |
- If External Storage is selected on the left side of the Object field, the following items can be selected.
|
Item on right side of Object field |
Item on left side of Monitor Data field |
Item on right side of Monitor Data field |
Unit of monitoring data |
|
Logical Device |
Data Trans. |
Total |
MB/s |
|
Read | |||
|
Write | |||
|
Response Time |
Total |
ms | |
|
Read | |||
|
Write | |||
|
Parity Group* |
Data Trans. |
Total |
MB/s |
|
Read | |||
|
Write | |||
|
Response Time |
Total |
ms | |
|
Read | |||
|
Write |
Available Objects table
The items appearing in the Available Objects table depend on the objects selected in the Performance Objects fields.
|
Monitoring object |
Item |
Description |
|
Fibre Port/Target and Fibre Port/Initiator |
Port ID |
Name of the port. Only the ports assigned to the user are displayed. |
|
iSCSI Port/Target and iSCSI Port/Initiator |
Port ID |
Name of the port. Only the ports assigned to the user are displayed. |
|
NAS Platform (User LU) / Target |
Port ID |
Name of the port. Only the ports assigned to the user are displayed. |
|
NAS Platform (System LU) / Target | ||
|
WWN/WWN |
HBA WWN |
Worldwide name of the host bus adapter. A WWN is a 16-digit hexadecimal number used as the unique identifier for a host bus adapter. Only the WWNs that correspond to the ports assigned to the user are displayed. |
|
WWN Name |
Nickname of the host bus adapter. A WWN name is up to 64 alphanumeric characters and some signs. | |
|
WWN/Port |
Port ID |
Name of the port. Only the ports assigned to the user are displayed. |
|
HBA WWN |
WWN of the host bus adapter. A WWN is a 16-digit hexadecimal number used as the unique identifier for a host bus adapter. | |
|
WWN Name |
Nickname of the host bus adapter. A WWN name is up to 64 alphanumeric characters and some signs. | |
|
Logical Device/Base |
LDEV ID |
ID of the volume, in the following format: LDKC:CU:LDEV. Only the LDEVs assigned to the user are displayed. |
|
LDEV Name |
Name of the LDEV. LDEV Name is the combination of fixed characters and numbers. | |
|
Logical Device/TC/TCMF/GAD |
LDEV ID |
ID of the volume, in the following format: LDKC:CU:LDEV. Only the LDEVs assigned to the user are displayed. |
|
LDEV Name |
Name of the LDEV. LDEV Name is the combination of fixed characters and numbers. | |
|
Logical Device/UR/URMF |
LDEV ID |
ID of the volume, in the following format: LDKC:CU:LDEV. Only the LDEVs assigned to the user are displayed. |
|
LDEV Name |
Name of the LDEV. LDEV Name is the combination of fixed characters and numbers. | |
|
Parity Group |
Parity Group ID |
ID of the parity group. Only the parity groups assigned to the user are displayed. |
|
LUN/Base |
Port ID
|
Name of the port. |
|
Host Group Name/iSCSI Target Alias
|
Name of the host group or iSCSI target alias. | |
|
LUN |
ID of the LUN. Only the LUNs that correspond to the host groups and LDEVs assigned to the user are displayed. | |
|
LUN/TC/GAD |
Port ID
|
Name of the port. |
|
Host Group Name/iSCSI Target Alias
|
Name of the host group or iSCSI target alias. | |
|
LUN |
ID of the LUN. Only the LUNs that correspond to the host groups and LDEVs assigned to the user are displayed. | |
|
LUN/UR |
Port ID
|
Name of the port. |
|
Host Group Name/iSCSI Target Alias
|
Name of the host group or iSCSI target alias. | |
|
LUN |
ID of the LUN. Only the LUNs that correspond to the host groups and LDEVs assigned to the user are displayed. | |
|
External Storage/Logical Device |
LDEV ID |
ID of the volume, in the following format: LDKC:CU:LDEV. Only the LDEVs assigned to the user are displayed. |
|
LDEV Name |
Name of the LDEV. LDEV Name is the combination of fixed characters and numbers. | |
|
External Storage/Parity Group |
Parity Group ID |
Parity group ID of the external volume. Only the parity groups assigned to the user are displayed. |
|
Controller/MP |
MP unit ID/MP ID |
ID of an MP unit and processor. |
|
Cache |
MP unit ID |
ID of an MP unit. |
|
Cache |
Name of the cache. | |
|
Entire Storage System/ TC/TC-MF/GAD |
Object |
Item for entire storage system. |
|
Entire Storage System/ UR/UR-MF |
Object |
Item for entire storage system. |
|
Journal/UR/URMF |
Journal ID |
ID of the journal. |