Extended copy time causes and corrective actions

The following table describes some causes and possible responses in the case of extended copy times.

Cause

Corrective action

A processor with an MP usage rate that exceeds 80% exists within the MP unit to which the P-VOL and S-VOL are allocated.

Examine the configuration.

For information about checking the MP usage rate, see the Performance Guide of your storage system.

The HOST I/O Performance option is enabled.

Disable the option (see System options).

The S-VOL's HDD or external storage performance is lower than the P-VOL's.

Make the configuration of the S-VOL's HDD or external storage the same as the P-VOL's.

The P-VOL's HDD or external storage has an error.

Review the error and make the necessary correction.

The S-VOL's HDD or external storage has an error.

Review the error and make the necessary correction.