Remote copy operations by TCand monitoring data by GAD (whole volumes)

The following table shows the file names and types of information on the Usage Monitor tab in the TC, and GAD window that can be exported to files using Export Tool. These files contain statistics about remote copy operations (whole volumes) by TrueCopy, and global-active device.

ZIP file

CSV file

Data saved in the file

RemoteCopy_dat.ZIP

RemoteCopy.csv

The following data in the whole volumes are saved:

  • The total number of remote I/Os (read and write operations)
  • The total number of remote write I/Os
  • The number of errors that occur during remote I/O
  • The number of initial copy remote I/Os
  • The average response time (milliseconds) for initial copy
  • The average transfer rate (Kbps) for initial copy remote I/Os
  • The number of update copy remote I/Os
  • The average transfer rate (Kbps) for update copy remote I/Os
  • The average response time (milliseconds) for update copy
  • The percentage of completion of copy operations (for example, number of synchronized pairs / total number of pairs)
  • The number of tracks that have not yet been copied by the initial copy or resync copy operation