EnvMonInfo.csv

This CSV file contains information about the power and temperature of the storage system. Power and temperature measurements from the environment monitor are recorded every two hours.

No records are created during a system power failure or if the breakers are turned off. If the system is in maintenance mode or the SVP is rebooted, up to two hours of records could be lost.

If a failure occurs in the storage system, the correct information might not be output.

Table 1: EnvMonInfo.csv file (Title: <<Electric power and temperature Information>>)

Item

Description

Date

Year, month, and date when record data was acquired for the two-hour period in the format:

YYYY/MM/DD HH:MM:SS

Electric power average

Average value of electric power (W)

Electric power maximum value

Maximum value of electric power (W)

Electric power minimum value

Minimum value of electric power (W)

In the following cases, a lower value might be temporarily displayed:

  • When the storage system is starting up
  • Right after replacing storage system parts
  • During or after microcode update

DKC0 CL1 Temperature average

DKC0: Average temperature of CL1 (°C)

DKC0 CL1 Temperature maximum value

DKC0: Maximum temperature of CL1 (°C)

DKC0 CL1 Temperature minimum value

DKC0: Minimum temperature of CL1 (°C)

DKC0 CL2 Temperature average

DKC0: Average temperature of CL2 (°C)

DKC0 CL2 Temperature maximum value

DKC0: Maximum temperature of CL2 (°C)

DKC0 CL2 Temperature minimum value

DKC0: Minimum temperature of CL2 (°C)