DkuTempMinInfo.csv
This CSV file contains information about DB temperature for every two hours. A record is DB temperature information obtained from the environment monitor. A record output to the first line shows the latest temperature information. Because DB temperature information is measured by DBPS, items are displayed in this unit*.
DkuTempMaxInfo.csv shows the maximum temperature as DB temperature data. The total number of items depends on the following model:
- (VSP G200: 17
- VSP G400/VSP G600/VSP F400/VSP F600: 49
- VSP G800/VSP F800: 97)
The DB temperature data displayed in DkuTempAveInfo.csv (average temperature only), DkuTempMaxInfo.csv (maximum temperature only), and DkuTempMinInfo.csv (minimum temperature only) is the same value as the DB temperature data for DkuTempInfo.csv.
If the system is in maintenance mode or the SVP is rebooted, the data that is output every two hours might not contain data for the period. If a failure occurs in the storage system, the correct information might not be output.
| Item | Description |
| Date |
Year, month, and date when temperature data was acquired in the format: YYYY/MM/DD hh:mm:ss |
|
DB00 DBPS001 Temperature minimum value |
Minimum temperature (°C) for the two-hour period of DB00 DBPS001 |
|
DB47 DBPS472 Temperature minimum value |
Minimum temperature (°C) for the two-hour period of DB47 DBPS472 For VSP G200, item shows up to DB07 DBPS072. For VSP G400, VSP G600, VSP F400, VSP F600, item shows up to DB23 DBPS232. |