Resolving errors when using CCI to perform Data Retention Utility operations (SSB1:2E31/B9BF/B9BD)
If an error occurs while using CCI to perform Data Retention Utility operations, you might identify the cause of the error by referring to the log appearing on the CCI window or the CCI operation log file.
The CCI operation log file is stored in the following directory.
/HORCM/log*/curlog/horcmlog_HOST/horcm.log
where
- * is the instance number.
- HOST is the host name.
The following is an example of a log entry in the CCI window.

The following table provides troubleshooting information for Data Retention Utility operations performed using CCI.
|
Error code (SSB2) |
Description |
|
9100 |
The command cannot be executed because user authentication is not performed. |
|
B9BD |
The setting failed because the specified volume does not exist. |
|
B9C2 |
The specified volume is a command device. |
|
B9C4 |
The command was rejected due to one of the following reasons:
|
|
B9C7 |
Data Retention Utility is not installed. |
|
B9C9 |
The consumed capacity exceeded the licensed capacity. |
|
B9CA |
The command was rejected due to one of the following reasons:
|
|
B9CB |
The retention term cannot be set because the access attribute is read/write. |