Cache capacity with capacity saving-enabled V-VOLs
I/O operations for capacity saving requires access to cached metadata. Metadata cache uses the same CLPR as the cache of user data.
The following table lists recommended cache capacity when all volumes in a storage system are capacity saving-enabled V-VOLs.
|
Total capacity of DRD-VOLs* (Effective Capacity) |
Recommended cache capacity (each CLPR) | |||
| VSP G200 | VSP G400 | VSP G600 | VSP G800 | |
| Less than 4TiB | 28GiB | 28GiB | 28GiB | 28GiB |
| 4TiB or more | 20GiB+X | 20GiB+X | 20GiB+X | 20GiB+X |
| 7.5TiB or more | 35GiB | 20GiB+X | 20GiB+X | 20GiB+X |
| 16TiB or more | 24GiB+X | 24GiB+X | 24GiB+X | |
| 31TiB or more | 86GiB | 24GiB+X | 24GiB+X | |
| 48TiB or more | 32GiB+X | 32GiB+X | ||
| 90.5TiB or more | 213GiB | 32GiB+X | ||
| 96TiB or more | 40GiB+X | |||
| 160TiB or more | 48GiB+X | |||
| 201.5TiB or more | 451GiB | |||
| X is the total capacity of DRD-VOLs x 0.2%
* DRD-VOL: data reduction volume, which is a DP-VOL with capacity saving enabled. | ||||