MpPcbStatus.csv

This CSV file contains information about the status of MP Unit. A record is created for each MP unit.

Table 1: MpPcbStatus.csv file (Title: <<MP PCB Status>>)

Item

Content

MPU ID

MP unit ID (MPU-10, MPU-11, MPU-20, MPU-21)

MPU-10 and MPU-20 are displayed if Unified Mode of DkcInfo.csv is On.

Auto Assignment

Information about whether this MP unit is set to be automatically assigned to each resource.

  • Enabled: Set to be automatically assigned
  • Disabled: Not set to be automatically assigned

PCB Status

MP unit status*

MP#00, #01,..., #07

MP status*

The number of output items differs for each model, because the number of installed MPs is different.

  • VSP G200: MP#00,01
  • VSP G400, G600 or VSP F400, F600: MP#00, 01,…, 03
  • VSP G800 or VSP F800: MP#00, 01,…, 07

Note:

  1. 1=Normal, 0=Abnormal