Pair status definitions
Device Manager - Storage Navigator displays both the Device Manager - Storage Navigator pair status name and the CCI pair status name, except when the names are the same. When they are the same, the CCI status is not displayed.
The following table lists and describes the pair status names.
|
HDvM - SN status |
CCI status |
Description |
P-VOL access |
S-VOL access |
|
(Unpaired- no HDvM - SN status) |
SMPL |
The volume is not assigned to a pair and is not in a journal. |
Read/Write |
Read/Write |
|
|
COPY |
The initial copy operation is in progress. |
Read/Write |
Read Only |
|
|
PAIR |
The pair is synchronized. Updates to the P-VOL are duplicated on the S-VOL. |
Read/Write |
Read Only |
|
HDvM - SN displays this status as
|
PFUL |
If data in the journal volume exceeds the threshold (80 %), pair status changes to PFUL. The pair is not suspended; the copy operation continues. If the journal option, Inflow Control, is set to Enable in HDvM - SN, or the modify journal command is executed in CCI when status changes to PFUL, host I/O is delayed because update I/O to the journal volume is delayed. |
Read/Write |
Read Only |
|
|
PSUS SSUS |
The pair has been split by the user and the P-VOL and S-VOL are no longer synchronized.
SSUS is the S-VOL’s split status name. See also UR PSUS types and behaviors. |
Read/Write |
Read Only, but if you enable the Secondary Volume Write option then split the pair from the primary site, it is Read/Write (Default is Disable). |
|
|
PSUE |
The pair is suspended by the system due to an error; it is not synchronized.
See also UR PSUS types and behaviors. |
HDvM - SN: Read/Write CCI: Read/Write if no error in P-VOL |
Read Only |
|
|
(No equivalent CCI status) |
The pair is not synchronized and in transition from the PAIR or COPY status to PSUS or PSUE status. |
Read/Write |
Read Only |
|
|
(No equivalent CCI status) |
The pair relationship is being deleted. When the operation is complete, the status changes to unpaired. |
Read/Write |
Read Only |
|
|
(No equivalent CCI status) |
|
Read/Write1 |
Read/Write2 |
|
|
(No equivalent CCI status) |
When used with TC, this status indicates that the pair status is changing to HOLD so that the delta resync pair can be created. Operations allowed on pairs in HOLDING status:
If the delta resync operation is run on a pair in HOLDING status, the operation could fail. If you specify Entire Copy for the Delta Resync Failure option (Change Journal Option dialog box), differential data is copied to an S-VOL. When used with GAD, preparing for delta resync. Delta resync execution will fail if the pair status is HOLDING. Specification of Entire Copy is invalid for the Delta Resync Failure option. Resync the UR pair in case of delta resync failure. |
Read/Write1 |
- |
|
|
(No equivalent CCI status) |
|
Read/Write1 |
- |
|
(No equivalent HDvM - SN status) |
PFUS |
This status results when the journal volume becomes full and suspends. Pair status changes from COPY, PAIR or PFUL to PFUS. The UR pair is suspended and the copy operation stops. Make sure to review configuration of the remote path and journal volume.
|
Read /Write |
Read Only, unless the write option is enabled. |
|
(No equivalent HDvM - SN status) |
SSWS |
After Takeover, SSWS is the status of the S-VOL. With this status, data can be written to the S-VOL. The copy flow between P-VOL and S-VOL is reversed by running the CCI horctakeover command or pairsplit -RS. Therefore, the S-VOL is ready for host write operations. During disaster recovery, the host can write data to the S-VOL in SSWS status at the intermediate site or secondary site. However, in a 3DC configuration in which three UR sites are combined, the host cannot write data to the S-VOL if the volume is shared by the mirror that includes the UR delta resync pair. |
Read Only |
Read/Write |
|
Notes:
| ||||

COPY
PAIR
PSUS
PSUE
Deleting