Workflow for 3DC cascade configuration with three UR sites
You must create two UR pairs for the two mirrors, create a delta resync pair, and allocate remote command devices to finish creating a 3DC cascade configuration with three UR sites.
When you create a 3DC cascade configuration with three UR sites, you must perform the following procedure after step 4 in Configuration workflow .
- Create a UR pair for the first mirror in the primary site. Specify from 0 to 3 for the mirror ID when you create a UR pair.
- Wait until the UR pair status has changed to PAIR.
- Create a UR pair for the second mirror in the intermediate site. Specify the restore journal volume and S-VOL for the master journal volume and P-VOL used in the first mirror. Specify from 0 to 3 for the mirror ID. Assign a mirror ID not used in step 1.
- Wait until the UR pair status is changed to PAIR. When you set up the delta resync configuration, use the steps from 5 to 7.
- Create a
UR delta resync pair with the primary and secondary site volumes by doing the following:
- Specify P-VOL for P-VOL in the primary site of the first mirror.
- Specify S-VOL for S-VOL in the secondary site of the second mirror.
- Specify from 0 to 3 for a mirror ID. Assign a mirror ID not used in the step 1 and 3.
- Allocate remote command devices for each two mirror IDs in the primary site.
Allocate remote command devices also for the UR delta resync pair's mirror ID.
- Allocate remote command devices for the mirror ID in the intermediate site.
- Allocate remote command devices for the mirror ID in the secondary site.
NoteWhen you delete a
UR pair of the first mirror created in step 1 or delete a
UR pair of the second mirror created in step 3, the delta resync mirror's
UR pair created in step 5 will also be deleted.
