Troubleshooting port and volume discovery problems
The following table shows corrective actions you can take for port and volume discovery problems. If you cannot resolve the issue, contact Hitachi Solution Support Center.
|
Problem |
Corrective action |
|
The port on the local storage system and port on the external system are not connected. |
Connect the External port of the local system and the external system port. |
|
The cable for the switch is not connected correctly, or the switch's port is blocked. |
Connect the cable to the correct port on the switch. Or change the port status to the normal status. |
|
Zoning for the switch is not set appropriately. |
Make sure the zoning configuration allows the External port of the local system to communicate with the external system port. |
|
External volume returned RESERVATION CONFLICT. |
Release the reserved state of the external volume. |
|
Port security is set on the external system. |
Cancel the port security setting or change the security of the external system so that the local system can access the port of the external system. |
|
No LU is configured on the external system port. |
Configure an LU on the port. |
|
External volume capacity is less than the supported capacity for Universal Volume Manager. |
Perform one of the following:
|
|
The external volume is configured as a management LU. |
If a management LU, such as Universal Xport LU, is configured on the external system port, perform one of the following:
|
|
Remote command devices of the external system are cascaded. |
Perform one of the following:
|
|
External system information retrieved by port discovery is not found in the profile information. |
Perform one of the following:
|
|
Login to the external system failed. |
Perform one of the following:
|
|
The external volume is not in Normal status, or a failure or error occurred in retrieving information from the external system. |
Make sure that the status of the external system or the external volume is Normal. |
|
VSP G200, G400, G600, G800, VSP F400, F600, F800 When adding an iSCSI path, the iSCSI port of the external storage system returns "Redirection". | VSP G200, G400, G600, G800 with firmware version 83-03-0x or earlier, and VSP F400, F600, F800 with firmware version 83-04-0x or earlier do not support login redirection of iSCSI, so disable this function in external storage systems. |
If none of the actions suggested in the table provide volume discovery, remove the cable connection between the local and external storage systems, and then reconnect the storage systems. After 30 seconds, retry the operation.