Add Remote Connection window
Use this window to connect storage systems for remote replication.
For complete UR or UR-MF information, see the section on configuring primary and secondary systems in the Universal Replicator User Guide or Universal Replicator for Mainframe User Guide.
Local Storage System
|
Item |
Description |
|
Model |
Local model. |
|
Serial Number |
Local serial number. |
Remote Storage System
|
Item |
Description |
|
Model |
Remote system's model.
HUS VM (19) and VSP Gx00 models and VSP Fx00 models (18) can be selected only when System is selected for Connection Type. If a value other than the above is specified, it is regarded as a storage system that will be supported in the future. In this case, in the Remote Connections window, the specified value will be enclosed by parentheses, such as (255), is displayed. |
|
Serial Number |
Last five or six digits of the remote system serial number, as follows:
(VSP Gx00 models and VSP Fx00 models) Note: When using virtual storage machine volumes, specify the serial number of the storage system. Do not specify the serial number of the virtual storage machine. |
Remote Paths
|
Item |
Description |
|
Path Group ID |
Path group identifier (00 to FF). Up to 64 path group IDs can be registered per storage system. Path group IDs can be selected when Connection Type is System. |
|
Minimum Number of Paths |
Minimum number of remote paths.
|
|
Select Type |
Select the port type.
|
|
Port ID (for local storage systems) |
Select the port identifier of the local storage system. |
|
Virtual Port ID (for local storage systems) |
Virtual port ID of the local storage system. Displayed when iSCSI is selected as the port type. |
|
Port ID (for remote storage systems) |
Select the port identifier of a remote storage system. A hyphen (-) is displayed if the number of valid paths is greater than the minimum number of paths. Clicking the hyphen deletes the text box of the port for the local and remote storage systems. |
|
IP address |
Select the IP type (IPv4 or IPv6) for the port of the remote storage system to enter the IP address. Displayed only when iSCSI is selected as the port type. |
|
TCP Port Number |
Enter the TCP port number of the remote storage system. Displayed only when iSCSI is selected as the port type. |
|
Add Paths |
Opens a dialog box for creating additional paths (maximum of eight). |
Options
|
Item |
Description |
|
RIO MIH Time |
Time limit between 10 and 100 seconds for the data-transfer operation to complete (15 is the default). |
|
Roundtrip Time (msec.) |
TC, TC-MF and GAD only. Time limit between 1 and 500 milliseconds for data copy from P-VOL to S-VOL (1 is the default). |