Edit Mirror Options window
Use this window to change a mirror’s options.
For instructions, in the Help Contents tab, click:
|
Item |
Description |
|
Path Watch Time |
Interval from the time a path becomes blocked to the time when the mirror is suspended. The Path Watch Time value can be specified using Minutes, Hours, or Days. The range is 1 to 59 minutes, 1 to 23 hours, or 1 to 30 days. |
|
Path Watch Time Transfer |
Indicates whether to transfer the master journal's Path Watch Time value to the mirror's secondary side (RCU). When transferred, the Path Watch Time values of the mirror's primary side (MCU) and the secondary side (RCU) will be consistent.
|
|
Copy Pace |
Pace for copying data during initial copy: Slower is the default, Medium, Faster. |
|
Transfer Speed |
Data transfer line speed in Mbps (megabits per second): 3, 10, 100, or 256. |
|
Delta Resync Failure |
Processing that takes place in the event of delta resync operation failure.
Delta Resync Failure cannot be set at the secondary site. Use Entire Copy if your journals are part of a multiple-journal configuration in a RAID Manager consistency group. When you use UR with GAD, NO COPY applies regardless of the setting. If delta resync processing fails, no processing is performed and the S-VOL is not updated. In that case, resync the UR pair. |