Edit Remote Connection Options window

You use this window to edit remote connection options, such as minimum paths and round trip time.

For complete information and instructions for TC or TC-MF, in Contents, click:

  • Monitoring and maintaining the TC/TC-MF system
  • Changing minimum paths, round trip time, other remote connection options

For complete UR or UR-MF information, see the section on modifying data-transfer time threshold in the Universal Replicator User Guide or Universal Replicator for Mainframe User Guide.

Selected Remote Connection table

Item

Description

Minimum Number of Paths

Minimum number of remote paths.

  • TC and TC-MF: The range is from 1 to 8, and the default is 1.
  • UR and UR-MF: The minimum number is set to 1, regardless of the number entered.

RIO MIH Time

Time limit between 10 and 100 seconds (default = 15) for the data-transfer operation to complete.

Round Trip Time

TC, TC-MF, and GAD only.

Time limit between 1 and 500 milliseconds for data copy from P-VOL to S-VOL (1 is the default).