Performance Monitor main window

This is the main window for monitoring performance on your storage system. From this window you can set up monitoring parameters, start and stop monitoring, and view performance graphs. To open this window, select Performance Monitor in the Device Manager - Storage Navigator main window.

  • Summary Information
  • Monitored CUs tab
  • Monitored WWNs tab

Buttons

Item

Description

Server Priority Manager*

Click to open the Server Priority Manager window, which allows you to prioritize/non-prioritize ports and WWNs and to create WWN monitor groups.

Monitor Performance

Click to open the Monitor Performance window where you can specify the monitoring objects and monitoring period. Up to 8 objects can be specified in one graph panel. Up to 16 objects can be specified in 4 graph panels.

Edit Monitoring Switch

Click to open the Edit Monitoring Switch window, which allows you to start and stop performance monitoring and specify how often to monitor statistics.

* Appears when the secondary windows are enabled in the Edit Information Display Settings window.

Summary information

Item

Description

Monitoring Switch

Current monitoring status:

Enabled: Performance Monitor is monitoring the storage system.

Disabled: The storage system is not being monitored.

Sample Interval

Current sampling interval, from 1 to 15 minutes, for which statistics are collected during short-range monitoring.

This value is available when Enabled is selected in the Monitoring Switch field. If Disabled is selected, a hyphen appears.

Number of Monitored CUs

  • Number, from 0 to 64, of CUs currently being monitored.

    Appears only for VSP G800 and VSP F800.

Number of Monitored LDEVs

Numbers of LDEV currently being monitored:

    • VSP G100 and VSP G200: 0 to 2,048
    • VSP G400, VSP G600, VSP F400, F600: 0 to 4,096
    • VSP G800, VSP F800: 0 to 16,384

Number of Monitored WWNs

Number, from 0 to 2048, of WWNs currently being monitored.

Monitored CUs tab

Use this tab to view information about the CUs that are currently being monitored.

Appears only for VSP G800, VSP F800, .

Item

Description

CU

CU number.

Number of LDEVs

Number of LDEVs included in the monitored CUs.

Edit CU Monitor Mode

Click to open the Edit CU Monitor Mode window, where you can change the monitoring status.

View CU Matrix

Click to open the View CU Matrix window, where you can view following monitoring statuses of CUs.

  • CU which is being monitored
  • CU which is scheduled to be monitored
  • CU which is scheduled to be released from monitoring

Export

Displays the window for outputting table information.

Monitored WWNs tab

Use this tab to view information about the WWNs that are currently being monitored.

Item

Description

Port ID

Name of the port of the monitored WWN.

HBA WWN

Host bus adapter ID of the monitored WWN.

WWN Name

A WWN name is up to 64 alphanumeric characters and some signs.

Status

Following statuses of the port connected with WWN.

Normal: All WWNs connected with the port are monitoring target objects.

Non-Integrity: The WWN is not monitored for the corresponding port, but monitored for other ports.

Edit WWN Monitor Mode

Click to open the Edit WWN Monitor Mode window.

Add New Monitored WWNs

Click to open the Add New Monitored WWNs window.

Edit WWN

Click to open the Edit WWN window.

Delete Unused WWNs*

Click to open the Delete Unused WWNs window.

Add to Ports*

Click to open the Add to Ports window.

Export*

Displays the window for outputting table information.