Shredding times
The following tables show the standard required times for shredding without host I/O, listed by drive type. The same standard times also apply to shredding encrypted drives. The standard required time in each table assumes the use of OPEN-V volumes.
Since each volume is overwritten three times with dummy data by default, Volume Shredder requires three times the time listed in the table below. If you want to change the default settings, use the formula shown above to calculate the time required.
(VSP G1x00 and VSP F1500) For DKxxx-JxxxSS/KxxxSS/HxxxSS disk drives
| Rotation per minute | RAID level | Standard required time* | |
| 15 Krpm | RAID 1 | 2D+2D | 90 minutes |
| RAID 5 | 3D+1P | 70 minutes | |
| 7D+1P | 35 minutes | ||
| RAID 6 | 6D+2P | 40 minutes | |
| 14D+2P | 20 minutes | ||
| 10 Krpm | RAID 1 | 2D+2D | 140 minutes |
| RAID 5 | 3D+1P | 90 minutes | |
| 7D+1P | 40 minutes | ||
| RAID 6 | 6D+2P | 45 minutes | |
| 14D+2P | 20 minutes | ||
| 7.2 Krpm | RAID 1 | 2D+2D | 200 minutes |
| RAID 5 | 3D+1P | 120 minutes | |
| 7D+1P | 50 minutes | ||
| RAID 6 | 6D+2P | 60 minutes | |
| 14D+2P | 25 minutes | ||
| *Data drive capacity is assumed to be 1 TB. | |||
(VSP G1x00 and VSP F1500) For flash drives (SSDs)
| Number of parity groups | RAID level | Standard required time* | |
| From 1 to 4 | RAID 1 | 2D+2D | 25 minutes |
| RAID 5 | 3D+1P | 20 minutes | |
| 7D+1P | 15 minutes | ||
| RAID 6 | 6D+2P | 20 minutes | |
| 14D+2P | 10 minutes | ||
| *Flash drive capacity is assumed to be 1 TB. | |||
(VSP G1x00 and VSP F1500) For FMDs
| Number of parity groups | RAID level | Standard required time* | |
| From 1 to 4 | RAID 1 | 2D+2D | 20 minutes |
| RAID 5 | 3D+1P | 10 minutes | |
| 7D+1P | 10 minutes | ||
| RAID 6 | 6D+2P | 10 minutes | |
| 14D+2P | 10 minutes | ||
| *FMD capacity is assumed to be 1 TB. | |||
(VSP Fx00 models and VSP Gx00 models) For DKxxx-JxxxSS/KxxxSS/HxxxSS disk drives
| Rotation per minute | Drive capacity | RAID level | Standard required time (minute) | ||||||
| VSP G130 | VSP G150 | VSP G350/VSP F350 | VSP G370/VSP F370 | VSP G700/VSP F700 | VSP G900/VSP F900 | ||||
| 15 Krpm | 300 GB | RAID 1 | 2D+2D | 120 | 105 | 100 | 95 | 95 | 90 |
| RAID 5 | 2D+1P | 130 | 110 | 105 | 95 | 95 | 95 | ||
| 3D+1P | 90 | 75 | 70 | 65 | 65 | 65 | |||
| 4D+1P | 70 | 65 | 55 | 50 | 50 | 50 | |||
| 5D+1P | 55 | 50 | 45 | 40 | 40 | 40 | |||
| 6D+1P | 45 | 45 | 40 | 35 | 35 | 35 | |||
| 7D+1P | 40 | 40 | 35 | 30 | 30 | 30 | |||
| 8D+1P | 35 | 35 | 30 | 30 | 30 | 25 | |||
| RAID 6 | 4D+2P | 70 | 60 | 55 | 50 | 50 | 50 | ||
| 6D+2P | 50 | 45 | 40 | 35 | 35 | 35 | |||
| 8D+2P | 40 | 35 | 30 | 30 | 30 | 25 | |||
| 10D+2P | 30 | 30 | 25 | 25 | 25 | 20 | |||
| 12D+2P | 30 | 25 | 20 | 25 | 25 | 20 | |||
| 14D+2P | 25 | 25 | 20 | 20 | 20 | 15 | |||
| 600 GB | RAID 1RAID 5 | 2D+2D | 110 | 95 | 90 | 85 | 85 | 80 | |
| 2D+1P | 120 | 75 | 70 | 75 | 75 | 75 | |||
| 3D+1P | 80 | 55 | 55 | 55 | 55 | 55 | |||
| 4D+1P | 65 | 45 | 40 | 40 | 40 | 40 | |||
| 5D+1P | 50 | 40 | 35 | 35 | 35 | 35 | |||
| 6D+1P | 45 | 35 | 30 | 25 | 25 | 25 | |||
| 7D+1P | 40 | 35 | 30 | 25 | 25 | 25 | |||
| 8D+1P | 35 | 35 | 30 | 25 | 25 | 25 | |||
| RAID 6 | 4D+2P | 65 | 55 | 50 | 45 | 45 | 45 | ||
| 6D+2P | 45 | 40 | 35 | 30 | 30 | 30 | |||
| 8D+2P | 35 | 30 | 25 | 25 | 25 | 25 | |||
| 10D+2P | 30 | 25 | 20 | 20 | 20 | 20 | |||
| 12D+2P | 25 | 25 | 20 | 20 | 20 | 15 | |||
| 14D+2P | 25 | 20 | 15 | 15 | 15 | 15 | |||
| 10 Krpm | 600 GB | RAID 1 | 2D+2D | 160 | 135 | 130 | 125 | 125 | 120 |
| RAID 5 | 2D+1P | 160 | 130 | 125 | 115 | 120 | 120 | ||
| 3D+1P | 110 | 90 | 85 | 80 | 85 | 85 | |||
| 4D+1P | 85 | 70 | 65 | 60 | 65 | 65 | |||
| 5D+1P | 70 | 60 | 55 | 50 | 50 | 50 | |||
| 6D+1P | 60 | 50 | 45 | 45 | 45 | 45 | |||
| 7D+1P | 50 | 45 | 40 | 40 | 40 | 40 | |||
| 8D+1P | 45 | 40 | 35 | 35 | 35 | 35 | |||
| RAID 6 | 4D+2P | 85 | 75 | 70 | 65 | 65 | 65 | ||
| 6D+2P | 60 | 55 | 50 | 45 | 45 | 45 | |||
| 8D+2P | 45 | 40 | 35 | 35 | 35 | 35 | |||
| 10D+2P | 40 | 35 | 30 | 30 | 30 | 30 | |||
| 12D+2P | 35 | 30 | 25 | 25 | 25 | 25 | |||
| 14D+2P | 30 | 30 | 25 | 20 | 20 | 20 | |||
| 1.2 TB | RAID 1 | 2D+2D | 155 | 140 | 135 | 130 | 130 | 130 | |
| RAID 5 | 2D+1P | 160 | 125 | 125 | 125 | 125 | 125 | ||
| 3D+1P | 110 | 90 | 85 | 85 | 85 | 85 | |||
| 4D+1P | 85 | 70 | 65 | 65 | 65 | 65 | |||
| 5D+1P | 70 | 55 | 55 | 55 | 55 | 55 | |||
| 6D+1P | 60 | 50 | 45 | 45 | 45 | 45 | |||
| 7D+1P | 50 | 45 | 40 | 40 | 40 | 40 | |||
| 8D+1P | 45 | 40 | 35 | 35 | 35 | 35 | |||
| RAID 6 | 4D+2P | 85 | 70 | 65 | 65 | 60 | 65 | ||
| 6D+2P | 60 | 50 | 45 | 45 | 45 | 45 | |||
| 8D+2P | 45 | 40 | 35 | 35 | 35 | 35 | |||
| 10D+2P | 40 | 35 | 30 | 30 | 30 | 30 | |||
| 12D+2P | 35 | 30 | 25 | 25 | 25 | 25 | |||
| 14D+2P | 30 | 25 | 20 | 20 | 20 | 20 | |||
| 1.8 TB | RAID 1 | 2D+2D | 155 | 130 | 125 | 105 | 105 | 105 | |
| RAID 5 | 2D+1P | 155 | 125 | 120 | 95 | 95 | 90 | ||
| 3D+1P | 105 | 85 | 80 | 65 | 65 | 60 | |||
| 4D+1P | 80 | 65 | 60 | 50 | 45 | 45 | |||
| 5D+1P | 65 | 55 | 50 | 45 | 40 | 40 | |||
| 6D+1P | 55 | 45 | 40 | 30 | 30 | 30 | |||
| 7D+1P | 50 | 40 | 35 | 35 | 30 | 30 | |||
| 8D+1P | 45 | 35 | 30 | 25 | 25 | 25 | |||
| RAID 6 | 4D+2P | 85 | 65 | 60 | 45 | 45 | 45 | ||
| 6D+2P | 50 | 40 | 35 | 30 | 30 | 30 | |||
| 8D+2P | 45 | 35 | 30 | 25 | 25 | 25 | |||
| 10D+2P | 40 | 30 | 25 | 20 | 20 | 20 | |||
| 12D+2P | 35 | 25 | 20 | 15 | 20 | 20 | |||
| 14D+2P | 30 | 25 | 20 | 15 | 15 | 15 | |||
| 2.4 TB | RAID 1 | 2D+2D | 145 | 125 | 120 | 115 | 115 | 115 | |
| RAID 5 | 2D+1P | 145 | 125 | 120 | 120 | 120 | 115 | ||
| 3D+1P | 100 | 85 | 80 | 75 | 75 | 75 | |||
| 4D+1P | 75 | 65 | 60 | 60 | 60 | 55 | |||
| 5D+1P | 65 | 55 | 50 | 50 | 50 | 45 | |||
| 6D+1P | 55 | 45 | 40 | 40 | 40 | 35 | |||
| 7D+1P | 50 | 40 | 35 | 35 | 35 | 30 | |||
| 8D+1P | 45 | 35 | 30 | 30 | 30 | 25 | |||
| RAID 6 | 4D+2P | 80 | 65 | 60 | 60 | 60 | 55 | ||
| 6D+2P | 50 | 40 | 40 | 40 | 40 | 35 | |||
| 8D+2P | 45 | 35 | 30 | 30 | 30 | 30 | |||
| 10D+2P | 35 | 30 | 25 | 25 | 25 | 20 | |||
| 12D+2P | 35 | 25 | 20 | 20 | 20 | 20 | |||
| 14D+2P | 30 | 25 | 20 | 20 | 20 | 15 | |||
| 7.2 Krpm | 6.0 TB | RAID 1 | 2D+2D | 215 | 165 | 160 | 160 | 160 | 160 |
| RAID 5 | 2D+1P | 210 | 155 | 150 | 135 | 135 | 135 | ||
| 3D+1P | 140 | 105 | 100 | 90 | 90 | 90 | |||
| 4D+1P | 110 | 80 | 75 | 70 | 70 | 65 | |||
| 5D+1P | 90 | 65 | 60 | 55 | 55 | 55 | |||
| 6D+1P | 75 | 55 | 50 | 45 | 45 | 45 | |||
| 7D+1P | 65 | 50 | 45 | 40 | 40 | 40 | |||
| 8D+1P | 60 | 45 | 40 | 35 | 35 | 35 | |||
| RAID 6 | 4D+2P | 110 | 80 | 75 | 65 | 65 | 65 | ||
| 6D+2P | 75 | 55 | 50 | 45 | 45 | 45 | |||
| 8D+2P | 60 | 45 | 40 | 35 | 35 | 35 | |||
| 10D+2P | 50 | 40 | 35 | 30 | 30 | 25 | |||
| 12D+2P | 40 | 35 | 30 | 25 | 25 | 25 | |||
| 14D+2P | 35 | 30 | 25 | 25 | 25 | 20 | |||
| 10.0 TB | RAID 1 | 2D+2D | 210 | 165 | 160 | 160 | 155 | 155 | |
| RAID 5 | 2D+1P | 205 | 155 | 150 | 130 | 115 | 115 | ||
| 3D+1P | 140 | 90 | 90 | 85 | 80 | 80 | |||
| 4D+1P | 105 | 80 | 75 | 65 | 60 | 60 | |||
| 5D+1P | 85 | 65 | 60 | 55 | 50 | 50 | |||
| 6D+1P | 70 | 55 | 50 | 45 | 40 | 40 | |||
| 7D+1P | 65 | 50 | 45 | 40 | 35 | 35 | |||
| 8D+1P | 55 | 45 | 40 | 35 | 30 | 30 | |||
| RAID 6 | 4D+2P | 105 | 80 | 75 | 70 | 60 | 60 | ||
| 6D+2P | 75 | 55 | 50 | 45 | 40 | 40 | |||
| 8D+2P | 55 | 45 | 40 | 35 | 30 | 30 | |||
| 10D+2P | 45 | 40 | 35 | 30 | 25 | 25 | |||
| 12D+2P | 40 | 35 | 30 | 25 | 20 | 20 | |||
| 14D+2P | 35 | 35 | 30 | 25 | 20 | 20 | |||
(VSP Fx00 models and VSP Gx00 models) For flash drives (SSDs)
| Drive capacity | RAID level | Standard required time (minute) | ||||||
| VSP G130 | VSP G150 | VSP G350/VSP F350 | VSP G370/VSP F370 | VSP G700/VSP F700 | VSP G900/VSP F900 | |||
| 480 GB | RAID 1 | 2D+2D | 15 | 20 | 15 | 15 | 15 | 15 |
| RAID 5 | 2D+1P | 25 | 20 | 15 | 15 | 15 | 15 | |
| 3D+1P | 20 | 15 | 10 | 10 | 10 | 10 | ||
| 4D+1P | 20 | 15 | 10 | 10 | 10 | 10 | ||
| 5D+1P | 15 | 15 | 10 | 10 | 10 | 10 | ||
| 6D+1P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 7D+1P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 8D+1P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| RAID 6 | 4D+2P | 20 | 15 | 10 | 10 | 10 | 10 | |
| 6D+2P | 20 | 10 | 5 | 5 | 10 | 5 | ||
| 8D+2P | 20 | 10 | 5 | 5 | 10 | 5 | ||
| 10D+2P | 20 | 10 | 5 | 5 | 5 | 5 | ||
| 12D+2P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 14D+2P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 960 GB | RAID 1 | 2D+2D | 15 | 20 | 15 | 15 | 15 | 15 |
| RAID 5 | 2D+1P | 25 | 20 | 15 | 15 | 15 | 15 | |
| 3D+1P | 20 | 15 | 10 | 10 | 10 | 10 | ||
| 4D+1P | 20 | 15 | 10 | 10 | 10 | 10 | ||
| 5D+1P | 15 | 15 | 10 | 10 | 10 | 5 | ||
| 6D+1P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 7D+1P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 8D+1P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| RAID 6 | 4D+2P | 20 | 15 | 10 | 10 | 10 | 10 | |
| 6D+2P | 20 | 10 | 5 | 5 | 5 | 5 | ||
| 8D+2P | 20 | 10 | 5 | 5 | 5 | 5 | ||
| 10D+2P | 20 | 10 | 5 | 5 | 5 | 5 | ||
| 12D+2P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 14D+2P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 1.9 TB | RAID 1 | 2D+2D | 15 | 20 | 15 | 15 | 15 | 15 |
| RAID 5 | 2D+1P | 25 | 20 | 15 | 15 | 15 | 15 | |
| 3D+1P | 20 | 15 | 10 | 10 | 10 | 10 | ||
| 4D+1P | 20 | 15 | 10 | 10 | 10 | 10 | ||
| 5D+1P | 15 | 15 | 10 | 10 | 10 | 10 | ||
| 6D+1P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 7D+1P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 8D+1P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| RAID 6 | 4D+2P | 20 | 15 | 10 | 10 | 10 | 10 | |
| 6D+2P | 20 | 10 | 5 | 5 | 5 | 5 | ||
| 8D+2P | 20 | 10 | 5 | 5 | 5 | 5 | ||
| 10D+2P | 20 | 10 | 5 | 5 | 5 | 5 | ||
| 12D+2P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 14D+2P | 15 | 10 | 5 | 5 | 5 | 5 | ||
| 3.8 TB | RAID 1 | 2D+2D | 15 | 15 | 15 | 15 | 15 | 15 |
| RAID 5 | 2D+1P | 25 | 15 | 15 | 15 | 15 | 15 | |
| 3D+1P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| 4D+1P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| 5D+1P | 15 | 10 | 10 | 10 | 10 | 10 | ||
| 6D+1P | 15 | 10 | 10 | 10 | 10 | 10 | ||
| 7D+1P | 15 | 5 | 5 | 5 | 5 | 5 | ||
| 8D+1P | 15 | 5 | 5 | 5 | 5 | 5 | ||
| RAID 6 | 4D+2P | 20 | 10 | 10 | 10 | 10 | 10 | |
| 6D+2P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| 8D+2P | 20 | 10 | 10 | 5 | 5 | 5 | ||
| 10D+2P | 20 | 5 | 5 | 5 | 5 | 5 | ||
| 12D+2P | 20 | 5 | 5 | 5 | 5 | 5 | ||
| 14D+2P | 20 | 5 | 5 | 5 | 5 | 5 | ||
| 7.6 TB | RAID 1 | 2D+2D | 15 | 15 | 15 | 15 | 15 | 15 |
| RAID 5 | 2D+1P | 25 | 15 | 15 | 15 | 15 | 10 | |
| 3D+1P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| 4D+1P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| 5D+1P | 15 | 10 | 10 | 10 | 10 | 10 | ||
| 6D+1P | 15 | 5 | 5 | 5 | 5 | 5 | ||
| 7D+1P | 15 | 5 | 5 | 5 | 5 | 5 | ||
| 8D+1P | 15 | 5 | 5 | 5 | 5 | 5 | ||
| RAID 6 | 4D+2P | 20 | 10 | 10 | 10 | 10 | 10 | |
| 6D+2P | 20 | 10 | 10 | 5 | 5 | 5 | ||
| 8D+2P | 20 | 10 | 10 | 5 | 5 | 5 | ||
| 10D+2P | 20 | 5 | 5 | 5 | 5 | 5 | ||
| 12D+2P | 20 | 5 | 5 | 5 | 5 | 5 | ||
| 14D+2P | 20 | 5 | 5 | 5 | 5 | 5 | ||
| 15.0 TB | RAID 1 | 2D+2D | 20 | 20 | 20 | 20 | 20 | 20 |
| RAID 5 | 2D+1P | 35 | 20 | 20 | 20 | 20 | 20 | |
| 3D+1P | 25 | 15 | 15 | 15 | 15 | 15 | ||
| 4D+1P | 25 | 15 | 15 | 15 | 15 | 15 | ||
| 5D+1P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| 6D+1P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| 7D+1P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| 8D+1P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| RAID 6 | 4D+2P | 30 | 15 | 15 | 15 | 15 | 10 | |
| 6D+2P | 30 | 15 | 10 | 10 | 10 | 10 | ||
| 8D+2P | 30 | 15 | 10 | 10 | 10 | 10 | ||
| 10D+2P | 30 | 15 | 10 | 10 | 10 | 10 | ||
| 12D+2P | 20 | 10 | 10 | 10 | 10 | 10 | ||
| 14D+2P | 20 | 10 | 10 | 10 | 10 | 10 | ||
(VSP Fx00 models and VSP Gx00 models) For FMDs
| Drive capacity | RAID level | Standard required time (minute) | ||||
| VSP G350/VSP F350 | VSP G370/VSP F370 | VSP G700/VSP F700 | VSP G900/VSP F900 | |||
| 3.2 TB | RAID 1 | 2D+2D | 5 | 5 | 5 | 5 |
| RAID 5 | 2D+1P | 5 | 5 | 5 | 5 | |
| 3D+1P | 5 | 5 | 5 | 5 | ||
| 4D+1P | 5 | 5 | 5 | 5 | ||
| 5D+1P | 5 | 5 | 5 | 5 | ||
| 6D+1P | 5 | 5 | 5 | 5 | ||
| 7D+1P | 5 | 5 | 5 | 5 | ||
| 8D+1P | 5 | 5 | 5 | 5 | ||
| RAID 6 | 4D+2P | 5 | 5 | 5 | 5 | |
| 6D+2P | 5 | 5 | 5 | 5 | ||
| 8D+2P | 5 | 5 | 5 | 5 | ||
| 10D+2P | 5 | 5 | 5 | 5 | ||
| 12D+2P | 5 | 5 | 5 | 5 | ||
| 14D+2P | 5 | 5 | 5 | 5 | ||
| 6.4 TB, 13.0 TB | RAID 1 | 2D+2D | 10 | 10 | 10 | 10 |
| RAID 5 | 2D+1P | 10 | 10 | 10 | 10 | |
| 3D+1P | 5 | 5 | 5 | 5 | ||
| 4D+1P | 5 | 5 | 5 | 5 | ||
| 5D+1P | 5 | 5 | 5 | 5 | ||
| 6D+1P | 5 | 5 | 5 | 5 | ||
| 7D+1P | 5 | 5 | 5 | 5 | ||
| 8D+1P | 5 | 5 | 5 | 5 | ||
| RAID 6 | 4D+2P | 5 | 5 | 5 | 5 | |
| 6D+2P | 5 | 5 | 5 | 5 | ||
| 8D+2P | 5 | 5 | 5 | 5 | ||
| 10D+2P | 5 | 5 | 5 | 5 | ||
| 12D+2P | 5 | 5 | 5 | 5 | ||
| 14D+2P | 5 | 5 | 5 | 5 | ||
When host I/Os are performed, the required shredding time is at least six times that of when no host I/Os are performed. If a DKxxx-HxxxSS data drive is used for creating a parity group on an encrypted data drive, the time required for shredding that parity group is the maximum time listed.
If the volumes to be shredded belong to drives of mixed types or mixed configurations, the longest required times associated with the drive type or drive configuration apply to all volumes. Thus, mixed types and configurations take more time for the volumes to become available for use than when the drive type and drive configuration are the same. When you add drives or change drive configurations, you should arrange the drives into those with the same standard required times, and then add drives starting with those volume types requiring the least shredding time.
When the emulation type for mainframe is selected for the LDEV, Fibre channel connectivity for mainframe is required. When the emulation type for open systems is selected, a channel for open systems is required.