Resync Pairs confirmation window
Selected Pairs table
The following table shows the items in this table in the Confirm window of the Resync Pairs wizard.
|
Item |
Description |
|---|---|
|
Primary Volume |
The P-VOL information. Values:
|
|
Copy Type |
The types of pairs. Values:
|
|
Snapshot Group |
HTI only. The snapshot group name. If you have not assigned the pair to a snapshot group, this item is blank. |
|
Status |
The status for the pair. For more information about pair status, click Show All Contents and then select In-System Replication to navigate to the desired software and status information. |
|
Resync Type |
The type of resynchronization. Values:
Resync pair from P-VOL to S-VOL.
Resync pair from S-VOL to P-VOL.
Resync pair from P-VOL to S-VOL and immediately change the status to PAIR.
Swaps the P-VOL and S-VOL. Default: Normal Copy (Primary > Secondary) For more information about the types of resynchronization, see the topic on types of pair resynchronization by clicking Show All Contents and then selecting In-System Replication to navigate to the desired software and information. |
|
Copy Pace |
SI only. The system option that determines the rate at which you want the VSP G200, G400, G600 storage system to copy data. Values:
|
|
Snapshot Date |
HTI only. The date and time that a snapshot was acquired. |
|
Secondary Volume |
The S-VOL information. Values:
|
|
Pool Name (ID) |
HTI only. The pool name and identification number. |
|
Mirror Unit |
The mirror unit number. |