View Pair Properties window
Use this window to review pair and volume details for local replication.
This window includes the following section and table:
Pair Properties section
Pairs table
For more information about this window, see the topic on monitoring pair and volume details by clicking Show All Contents and then selecting In-System Replication to navigate to the desired software and information.
Pair Properties section
The following table shows the items in this section of the View Pair Properties window.
|
Item |
Description |
|---|---|
|
Copy Type |
The type of pair. Values:
Default: ShadowImage |
|
Pool Name (ID) |
HTI only. The pool name and identification number. If you have not set a pool name for the pair, this item is blank. |
|
Most Recent Snapshot Date |
HTI only. The date and time you acquired the most recent snapshot. If you have not acquired a snapshot, this item is blank. |
|
LDEV ID |
The identification number of the LDEVs for the P-VOL and S-VOLs. |
|
LDEV Name |
The name of the LDEVs for the P-VOL and S-VOLs. |
|
Mirror Unit |
The mirror unit number. |
|
Virtual Storage Machine |
The model type and serial number of the virtual storage machine to which the P-VOL and S-VOL belong. |
|
Virtual LDEV ID |
The identification number of the virtual LDEV for the P-VOL and S-VOLs. If no virtual LDEV ID is assigned, a blank displays. |
Pairs table
The following table shows the items in this table on the View Pair Properties window.
|
Item |
Description |
|---|---|
|
Primary Volume |
The P-VOL information. Values:
|
|
Snapshot Group |
HTI only. The snapshot group name. If you have not assigned the pair to a snapshot group, this item is blank. |
|
Status |
The status for the pair. For more information about pair status, navigate to the desired software and status information. To do this, click Show All Contents and then select In-System Replication. |
|
Secondary Volume |
The S-VOL information. Values:
- W is shown when the VSP G200, G400, G600 storage system has written data to the S-VOL. W is also shown when the VSP G200, G400, G600 storage system has written data to the S-VOL and the S-VOL cannot be read when its pair status is "PSUS(SP)/PSUS" or "PSUS". - N is shown when the S-VOL cannot be read because you specified "-m noread" using the CCI. - A hyphen (-) indicates that the VSP G200, G400, G600 storage system has not written to the S-VOL.
- W is shown if the VSP G200, G400, G600 storage system has written data to the S-VOL when its pair status is "PSUS(SP)/PSUS" or "PSUS". - A hyphen (-) indicates that the VSP G200, G400, G600 storage system has not written to the S-VOL. |
|
Secondary Volume (continued) |
Values (continued):
|
|
Snapshot Date |
HTI only. The date and time the snapshot was acquired. |
|
CTG ID |
The identification number for the CTG to which the pair is assigned. |
|
Copy Pace |
SI only. The system option that determines the rate at which you want the VSP G200, G400, G600 storage system to copy data. |
|
Mirror Unit |
The mirror unit number. |